![Zte ZXSDR BS8908 G060 User Manual Download Page 65](http://html1.mh-extra.com/html/zte/zxsdr-bs8908-g060/zxsdr-bs8908-g060_user-manual_940278065.webp)
Chapter 5 Installation
Figure 5-29 AC Power Cable Structure
1.
4-core round connector
2.
End B signal label
lists the core color and definition of the AC power cable.
Table 5-7 AC Power Cable Cores
Core Color
Definition
Brown
L (live wire)
Yellow/green
PE
Blue
N (neutral wire)
Steps
1.
Remove the protective cap of the power interface.
2.
Align end A of the power cable with the power interface's red point, insert it into the
interface, and tighten it.
3.
Protect end A with the insulating tape.
4.
Peel off the sheath of end B of the power cable. Connect the power supply equipment
according to the core color.
5.
Paste labels at the two ends of the power cable.
6.
Fix the power cable.
– End of Steps –
5.7.4 Installing Grounding Cable
Prerequisites
l
Wear the antistatic wrist strap.
l
The cabinet installation is completed.
l
The grounding system and connection points of indoor and outdoor copper grounding
bars have been constructed completely.
Context
The grounding cable of BS8908 is made of the 25 mm
2
yellow/green fire-resistant
multi-strand wires.
End A of the cable is in crimp connection with the double-hole
5-35
SJ-20101104174421-001|20110425(R1.1)
ZTE Proprietary and Confidential
Summary of Contents for ZXSDR BS8908 G060
Page 5: ...Glossary V III ...
Page 6: ...IV ...