ZXR10 2900E Series Configuration Guide
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 relate-to rmep-id 2
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 one-lm (two-lm)
enable
Configuration on S2:
zte(cfg)#cfm enable
zte(cfg)#create cfm md-session 1 name zte_1 level 5
zte(cfg)#create cfm md-session 1 ma-session 1 name zte_zte_1
zte(cfg)#cfm md-session 1 ma-session 1 primary-vlan 100
zte(cfg)#create cfm md-session 1 ma-session 1 mep-session 1 mep-id 2 direction down
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 state enable
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 ccm-send enable
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 ccm-receive enable
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 assign port 4
zte(cfg)#create cfm md-session 1 ma-session 1 rmep-session 2 rmep-id 1 remote-mac
00.d0.d0.c0.00.01
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 ccm-receive enable
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 relate-to rmep-id 1
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 2 one-lm (two-lm)
enable
l
Configuration Verification
LM on both ends is automatically performed based on the CCM configuration. While
LM on one end is performed after manually triggering on S1 or S2:
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 (2)
one-lm send-packet
View the measurement result by using the command for displaying MEP information
that is provided by 802.1ag.
DM Network Configuration
l
Configuration Description
The network configuration is illustrated by using the network instance shown in
Figure
4-61
.
Figure 4-61 DM Network Configuration Instance
l
Configuration Procedure
Configuration on S1:
zte(cfg)#cfm enable
zte(cfg)#create cfm md-session 1 name zte_1 level 5
4-146
SJ-20120409144109-002|2012-07-02(R1.0)
ZTE Proprietary and Confidential