9
Information: 4 closing flaps are included
to completely air tighten the unit from
the inside cover panel.
Place the flaps on the outside of the
interior cover panel to seal the air slots.
We also recommend turning the unit off.
Connect the wires from left to right into
the clamp. Please make sure to follow
the number/color code.
Break out the middle piece of the frame
and guide the cable through. Then
attach the frame to wall and or the wall
mounted box.
There must be a 6-wire control line
(6 x 0,1 mm² minimum) installed from the
ventilation unit to the control panel. Max
length should not exceed 25 meters.
1-brown, 2-red (purple), 3-blue, 4-white,
5-green, 6-yellow
4.3 Control panel installation
1
It is recommended to use a flush mounted
box when installing the control panel. This
makes the installation much easier.