40
Flange
F04
F05
F07
F10
F12
ø
d1
65
65
90
125
150
ø d2
f8
30
35
55
70
85
ø
d3
42
50
70
102
125
d4
M6
M6
M8
M10
M12
d7
H9
18
22
28
42
50
h3 max.
3
3
3
3
3
h2 min.
12
12
13
16
20
h1 max.
3
3
3
3
3
I1 min.
26
30
35
45
55
b4
Js 9
6
6
8
12
14
+0,4
t3
+0,2
20,5
24,5
30,9
45,1
53,5
ø d5
25
28
40
50
70
Connecting dimensions of
MODACT MOKP Ex
electric actuators
– connecting with keyway
h2
h1
h3
I1
ø
d1
ø
d2
ø
d5
t3
b4
ø
d3
“O”
“Z”
(“C”)
ø
d7
d4
The position of groove for
keyway according to ISO
5211 and DIN 3337 is in
the position “Closed”.
The position “Opened” is to
the left of the position
“Closed” when viewing in
the direction to the local
indicator of position.
The position “Z”
(“C”)
of
the groove for keyway is
identical with the position
“Z”
(“C”)
on the local
indicator of position.
Summary of Contents for Modact MOKP 100 Ex Series