Flame Failure Device;
Hobs equipped with flame failure device provide security in case of accidentally
extingnished flame. If such a case occurs, the device will block the burners gas channels
and will avoid any accumulation of unburned gas. Wait 90 seconds before re-igniting an
extinguished gas burner.
Necessary time period to arm the gas safety during ignition :max. 10 seconds
Necessary time period to disarm the gas safety after the flame extinguishes: Not more
than 90 seconds for the gas burners.
If your hob is equipped with gas safety device;
*Push the control knob and turn it counter clockwise until it reaches maximum flame
position.
*Approach a match or use electric ignition button if it is available to gas burner cap and
maintain the control knob pressed down for max. 10 seconds
*Let the control knob go and make sure that the gas burner stays ignited. If this fails,
repeat the procedure.
Recommandations:
Your hob is composed with of burners different diameters. The most economic way of
using gas is too choose the correspanding gas burners for your cooking pan size and to
bring the flame to minimum position once the boiling point is reached. It is recomended
to always cover your cooking pan.
In order to obtain maximum performance from the burners, use pots with the following
flat bottom diameters.
Rapid/Wok Burner : 22-26 cm
Semi Rapid Burner : 14-22 cm
Auxillary Burner : 10-18 cm
When the burners are not in use always leave the general gas control valve off. In
appliance equipped with wok burners wok grid adapter must be used whenever the wok
burner is used.
12