Using the 

Propaq MD Battery Pack 

The 

Propaq MD Battery Pack

 provides enhanced on-board processing that allows the battery to 

communicate its specific charging requirements to the 

SurePower

 

 Charger Station

 or Propaq 

MD unit. The battery’s on-board processing also allows it to provide the following information:

The battery’s run time or capacity.

The battery’s calibration status.

Battery Fault Indications.

Figure 1-1 ZOLL 

Propaq MD Battery Pack

Note:

ZOLL ships the 

Propaq MD Battery Pack

 in a partially charged state and you must 

fully charge the battery before first use.

It is very important that you recharge a depleted 

Propaq MD Battery Pack

 as soon as possible.

Caution

Do not store fully depleted batteries or damage can result.

Caution

Do not store fully charged batteries for more than 90 days. Should you need to store a battery for 

90 days or longer, see the 

Extended Storage 

section of this guide for information on how to do 

so.

"

Š

,ITHIUM)ON"ATTERY

=2//

Š

Summary of Contents for Propaq MD Battery Pack

Page 1: ...Propaq MD Battery Pack Guide ITHIUM ON ATTERY 2 9650 0809 01 Rev A...

Page 2: ...al Corporation to determine if additional product information updates are available ZOLL is a registered trademark and SurePower is a trademark of ZOLL Medical Corporation Propaq is a registered trade...

Page 3: ...tery Pack be dropped inspect and test the unit prior to further use following the procedures described in the Maintenance section of this Guide Avoid prolonged exposure of the Propaq MD Battery Pack t...

Page 4: ...fibrillator and battery Cautions Follow all recommended maintenance instructions If a problem occurs obtain service immediately Do not use alcohol or ketones MEK acetone etc to clean Propaq MD Battery...

Page 5: ...ttery s calibration status Battery Fault Indications Figure 1 1 ZOLL Propaq MD Battery Pack Note ZOLL ships the Propaq MD Battery Pack in a partially charged state and you must fully charge the batter...

Page 6: ...mately 10 seconds to indicate the battery s estimated run time If the battery is fully charged the LED over each of the five runtime indicator icons illuminates As the battery discharges the number of...

Page 7: ...ndications This is the Recalibration icon This LED lights for approximately 10 seconds after you press and release the Display button if the battery needs to be calibrated If the Recalibration LED lig...

Page 8: ...untime indicator displays the battery runtime When you release the Display button the runtime indicator displays the battery capacity for 2 seconds then redisplays the battery runtime During the 2 sec...

Page 9: ...ault there will be a brief delay before the LED blinks The fault codes number from 1 to 29 To indicate fault code 1 the Fault LED blinks once To indicate fault code 2 the LED blinks twice and so on If...

Page 10: ...t in 17 8 Length x 9 3 Width x 3 Height cm Weight 1 4 lb 64 kg Voltage 11 1 V Capacity 6 6 Ah when charged to 12 6V Operating Temperature 32 F to 122 F 0 C to 50 C Optimal Charging Temperature 59 F to...

Reviews: