CV-TYQ_1617_E_20180329
16
17
4
●
If mineral or Alkalized Ionic water is
used, calcium tends to build up on
the surface of the Inner Container. If
scale accumulates on the Inner
Container or the Filter, boiling may
become louder than usual and water
may not dispense smoothly.
Frequent cleaning is recommended
when using mineral or Alkalized Ionic
water.
To cancel the Citric Acid Cleaning at any time,
unplug the Power Plug for more than 5 seconds.
●
Repeated citric acid cleaning may
be necessary for hard-to-remove
residues or if water does not
dispense smoothly.
NOTE
●
Take precaution with the hot water
and steam. You may scald yourself.
●
Take precaution as hot water may
drip from the Spout, causing scalds.
When disposing hot water:
3
P.16
P.2
P.8
P.7
P.9
Is it okay to use the product for
heating liquids other than water?
Do not fill the product with any liquid other than water. It may cause
malfunction, or may overflow and cause scalding.
Is it okay to use mineral
water or Alkalized Ionic
water?
Yes. However, when mineral or Alkalized Ionic water is used, a floating
residue may develop or milky white substance may form on the surface of the
Inner Container. This is due to the ingredients in the water and is harmless to
your health. Frequent cleaning is recommended.
I accidentally drank water while
performing the Citric Acid Cleaning.
Is this harmful to my health?
Please follow the instructions shown on the package of the citric acid
cleaner CD-K03E-JU.
Is it okay to go out while
the product is turned on?
It is safe to use the product unattended as it has an Automatic Shut-Off function (power
to the heater will be automatically turned off), which will be activated once it is empty of
water. However be careful not to repeat the boiling process without filling the Inner
Container with water, as the Nonstick Coating may discolor and peel.
Does the water need to be
changed every day?
To prevent scale from building up, please change the water at least once a
day.
Check that the Filter is attached
to the Inner Container.
Preparation:
●
If the Filter is dirty, remove
it from the Inner Container,
wash with a soft brush and
reinstall.
NOTE
2
Beeps when the cleaning process is completed.
Turns on
5 long beeps
※
Cleaning times may vary
depending on the amount
of water, water
temperature and room
temperature.
Approx. 1.5 hours.
Cleaning time:
1
Beep
Beeps when the cleaning process begins.
In order to prevent gas bubbles and bubbling-over, the Citric Acid Cleaner for
Electric Water Boilers (CD-K03E-JU) is recommended for cleaning. To
purchase this cleaner, please visit an authorized Zojirushi dealer.
NOTE
Blinks
2 lights will
blink.
LCD display will
show a square as
illustrated.
The square
shown on the
Display rotates.
2 lights will stop
blinking and stay
on.
Unplug the Power Plug, detach the
Upper Lid and dispose water where
indicated "EMPTY FROM HERE."
(Please take precautions not to splash water
on the Hinge.)
To rinse, fill the Inner Container with
water. Boil and dispense about a cup of
hot water to rinse out the Spout, allow to
cool, then dispose the remaining water.
Q&A ON PRODUCT USE
Please check the following
points before calling for service.
TROUBLESHOOTING GUIDE
Condition
Cause
Remedy
The product has not been used for a long
time.
Hot water has a
disagreeable odor.
●
A mild plastic odor may be
noticeable with a new product.
This odor will gradually fade
away.
●
You may smell chlorine (used
for sterilization of tap water)
after boiling.
Boil water, unlock and dispense
about 1 liter of hot water. Discard
the remaining. (see pg.7)
If this is an issue, use the regular Boil
mode instead. (see pg.12)
The regular Boil mode purges chlorine
in tap water by boiling completion.
Scale or other residue has accumulated
on the Inner Container.
You have not performed citric acid
cleaning regularly.
Perform citric acid cleaning.
(see pg.16)
If tap water is used under Quick Temp
Function, it will take an additional 15
minutes after heating completes at the set
temperature removing up to 80% of the
chlorine.
Do not drink
the water used
for citric acid
cleaning.
HOW TO PERFORM CITRIC ACID CLEANING
Put 1 package of the Citric Acid Cleaner
CD-K03E-JU in a cup and add warm water to
dissolve. Pour it into the Inner Container and
fill with water to the Maximum Water Level Line.
●
Do not fill over the
Maximum Water Level
Line. (Hot water may spill
out, resulting in scalds.)
NOTE
Close the Upper Lid, insert the Power Plug and press the button for
more than 3 seconds.
625702-00
BF297053G-00
CD-K03E-JU
REPLACEMENT PARTS
●
Replacement parts may be available for an
additional charge. Please replace damaged parts
only with new parts.
●
When replacing parts, please record the model
number and part name beforehand. Then contact
the retail store where you purchased this product.
Parts Names
Parts Number
Citric Acid Cleaner for Electric
Water Boilers (30g
×
4 packets)
Inner Lid Gasket
Filter
Perform every 1-3 month(s) of usage
Water does not heat up.
Connect the Power Plug.
Power Plug is not connected to an
electrical outlet.