WARNING - THIS APPLIANCE MUST BE EARTHED
How to change the Fuse
If the Power Plug of your Power Cord (See P.4) is,
A. A type that can be disassembled. Refer to above.
B. A solid molded type that can not be disassembled. Please refer to the following.
1. Open the Fuse Cover of the Power Plug.
2. Replace the Fuse (13A) that is inside with a new Fuse. (Be sure to replace
with a 13A Fuse)
3. Fit back the Fuse Cover with the new Fuse to the Power Plug.
Do not connect the Fuse directly to the Power Plug. The Fuse
Cover can not be attached.
GREEN AND YELLOW
13 AMP FUSE
BROWN
BLUE
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code:
Green-and-yellow:Earth Brown:Live Blue:Neutral
If the colours of the wires in the mains lead of this appliance do not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows.
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked with the
letter E or by the earth symbol or coloured green or green-and-yellow. The wire which is coloured blue must be
connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured RED.
This appliance must be protected by a 13A fuse if a 13A (BS1363) plug is used
or, if any other type of plug is used, by a 10A fuse either in the plug or adaptor
or at the distribution board.
Caution
Power Plug
Fuse Cover
Fuse
(13A)
Fuse Cover
Always follow basic safety precautions when using electrical appliances.
Read all instructions carefully.
Please keep this instruction book on hand for easy reference.
INDEX
BOIL MODE
DISPENSE HOT WATER
DISPOSE WATER
AUTOMATIC SHUT-OFF FUNCTION
REBOIL MODE
HOW TO SET THE KEEP WARM MODE
QUICK TEMP MODE
ENERGY-SAVING MODE
ENERGY-SAVING TIMER FUNCTION
CAFÉ DRIP FUNCTION
HOW TO CHANGE THE INFORMATION
SOUND
6
8
8
9
9
10
12
13
13
14
14
IMPORTANT SAFEGUARDS
PARTS NAMES AND FUNCTIONS
2
4
HOW TO USE
BEFORE USE
USEFUL FUNCTIONS:
●
The average Keep Warm electric power consumption is for one hour, provided that the Inner
Container is full and the room temperature is approximately 23
。
C.
●
The height refers to the product when the handle is down.
●
In high altitudes or severely cold areas, the product may not perform as specified. Avoid using the
product in such areas or in other extreme conditions.
●
This product is not suitable for use in countries or regions with different power supply voltages or
frequencies.
SPECIFICATIONS
CD-TYQ40
AC 220-230V 50/60Hz
640-700W
0.75 m
Approx.
24
W
Approx.
21
W
Approx.
17
W
Approx.
13
W
4.0 liters
98
。
C
90
。
C
80
。
C
70
。
C
Model No.
Capacity
Rating
Electric Consumption
Length of the Power Cord
Weight (including the Power Cord)
External Dimensions (approx. cm)
Average Power
Consumption
during Keep
Warm
21 (W) x 28.5 (D) x 35 (H)
Approx.
3.2 kg
Q&A ON PRODUCT USE
TROUBLESHOOTING GUIDE
SPECIFICATIONS
CLEANING AND MAINTENANCE
BEFORE CALLING FOR SERVICE
17
17
20
CLEANING AND MAINTENANCE
HOW TO REPLACE THE
INNER LID GASKET
15
15
REPLACEMENT PARTS
17
16
HOW TO CLEAN THE INNER
CONTAINER WITH CITRIC ACID
●