36
4
、
For an example, if the existing version is 2, operator can restore it to 0 or 1 (smaller than the
current version number in all). And then press
to confirm the restored version number
and turn off the Sewing LED
;
1
、
Press
to quit the setting mode of service parameters. Then the system will return to the
normal sewing mode;
2
、
And then, turn off the power and repower the machine after about one minute. At the moment,
“EEP
——
” will be displayed on the operation panel. After 20 seconds, the operation panel
will become to display normally (attention: it is a normal phenomenon because the system
needs some time to perform the recovery of the default software).
3
、
After the recovery, the system will set the current software version as the highest version. For
example, there are 2 default versions, Version 1 & Version 0; in that case the version after the
recovery will be defined at 2 automatically.