30
2.5.3 Table for Parameter Setting
No. Functions
Adjustment
Range
Default
Value
Remarks
1.30
Max Speed of Sewing
(
it can be set in step of 1000rpm
)
400
~
3000
3000
2.15
Sewing speed of 1
st
Stitch (thread-catching)
(It can be set in step of 100rpm)
400
~
1500
1500
3.30
Sewing speed of 2
nd
Stitch (thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
4.30
Sewing speed of 3
rd
Stitch (thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
5.30
Sewing speed of 4
th
Stitch (thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
6.30
Sewing speed of 5
th
Stitch (thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
9.--
Changeover time of thread tension at
thread-trimming
-
6
~
4
0
Unavaila
ble in
1900B
10. 4
Sewing speed of 1
st
Stitch ( no thread-catching)
(It can be set in step of 100rpm)
400
~
1500
400
11. 9
Sewing speed of 2
nd
Stitch ( no thread-catching)
(It can be set in step of 100rpm)
400
~
3000
900
12.3
0
Sewing speed of 3
rd
Stitch (no thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
13.3
0
Sewing speed of 4
th
Stitch (no thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
14.3
0
Sewing speed of 5
th
Stitch (no thread-catching)
(It can be set in step of 100rpm)
400
~
3000
3000
15.--
Thread tension of 1
st
stitch
(
no thread-catching
)
0
~
200
0
Unavaila
ble in
1900B
16.--
Changeover timing of thread tension at the sewing
start
(
no thread-catching
)
-
5
~
2
0
Unavaila
ble in
1900B
17. 0
Whether to change or indicate the XY scale rate
and max speed limitation
0
:
changeable
1
:
unchangeable
0
18. 0
Action of Counter
0
:
Production
Counter(Add
ing Method)
1
:
Bottom
0