Manufacturer  warrants,  to  the  purchaser  and  subsequent  owner  during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used and 

maintained, for a period of one year from date of purchase by the end user, or 

18 months from date of original manufacture of the product, whichever comes 

first.  Parts that fail within the warranty period, one year from date of purchase 

by the end user, or 18 months from the date of original manufacture of the 

product, whichever comes first, that inspections determine to be defective 

in material or workmanship, will be repaired, replaced or remanufactured 

at Manufacturer's option, provided however, that by so doing we will not be 

obligated to replace an entire assembly, the entire mechanism or the complete 

unit.  No allowance will be made for shipping charges, damages, labor or 

other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any 

material or product that has been disassembled without prior approval 

of Manufacturer, subjected to misuse, misapplication, neglect, alteration, 

accident or uncontrolled act of nature; that has not been installed, operated 

or maintained in accordance with Manufacturer's installation instructions; 

that has been exposed to outside substances including but not limited to 

the following:  sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon 

derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive 

substances, wash towels or any other abusive entity, etc. in all pumping 

applications.  The warranty set out in the paragraph above is in lieu of 

all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in 

connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211 

USA, Attention: Customer Support Department to obtain any needed repair 

or replacement of part(s) or additional information pertaining to our warranty.

MaNUfaCTURER EXpRESSLy DISCLaIMS LIaBILITy fOR SpECIaL, 

CONSEQUENTIaL OR INCIDENTaL DaMagES OR BREaCH Of 

EXpRESSED OR IMpLIED WaRRaNTy; aND aNy IMpLIED WaRRaNTy 

Of fITNESS fOR a paRTICULaR pURpOSE aND Of MERCHaNTaBILITy 

SHaLL BE LIMITED TO THE DURaTION Of THE EXpRESSED WaRRaNTy.

Some jurisdictions do not allow limitations on the duration of an implied 

warranty, so the above limitation may not apply to you. Some jurisdictions do 

not allow the exclusion or limitation of incidental or consequential damages, 

so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other 

rights which vary from jurisdiction to jurisdiction.

LIMITED WARRANTY

HELpfUL HINTS fOR EaSy INSTaLLaTION

  1.  Read all instructions before beginning installation.

  2.  Be sure the floor is level within 3 mm (1/8").

  3.  Install vent pipe seal with flange side of seal on outside of lid.

  4.  Use soapy water to lubricate all seals to aid installation.

  5.  Install rubber coupling/union in vent line to aid disassembly.

  6.  Do not over torque toilet mounting screws.

  7.  Do not use an automatic plumbing vent device.

  8.  Obtain model number and date code, and record information in the 

space provided on the front of this manual. Refer to this information 

when calling the factory.

DO’S aND DON'T’S fOR INSTaLLINg a UNIT

  1.  DO read all installation material with the unit.

  2.  DO inspect unit for any visible damage caused by shipping. Contact 

dealer if unit appears to be damaged.

DO’S aND DON'T’S, 

continued

  3.  DO clean all visible debris from the unit.

  4.  DO always disconnect pump from power source before handling. 

DO always connect to a separately protected and properly grounded 

ground fault protected circuit. DO NOT ever cut, splice or damage 

power cord. DO NOT carry or lift pump by its power cord. DO NOT 

use an extension cord.

  5.  DO  install  a  ball  or  gate  valve  and  a  union  in  the  discharge  line 

downstream of the check valve.

  6.  DO test pump immediately after installation to be sure that the system 

is working properly.

  7.  DO review all applicable local and national codes and verify that the 

installation conforms to each of them.

  8.  We DO NOT recommend this product be connected to utilities other than 

those found in a normal bathroom application. Washing machines and 

dishwashers are examples of equipment that we DO NOT recommend.

  9.  DO inspect and test system for proper operations at least every 3 months.

TYPICAL PIPING CONFIGURATIONS

SK2587

Installation may not be 

exactly as shown.  Refer 

to step 1 on page 5 for 

piping details.

2.4 m (8') 

CEILING *

2.1 m (7') 

CEILING *

20.32 cm (8") min.

CHECK VALVE

P/N 30-0181

* Ceiling heights shown for reference only.

NOTE:  all installations must 

comply with all applicable 

governing codes.

Summary of Contents for QWIK JON ULTIMA 202

Page 1: ...1 28 or 1 6 gallons per flush 5 All fixtures connecting to the system must be on the same floor level 1 To reduce the risk of electrical shock a properly grounded receptacle or control box must be in...

Page 2: ...ABILITY SHALLBELIMITEDTOTHEDURATIONOFTHEEXPRESSEDWARRANTY Some jurisdictions do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some jurisdict...

Page 3: ...on Ultima Sewage Removal System 202 1001 202 1005 202 1002 202 1003 202 1010 202 1006 202 1012 2 Replacement pump with discharge pipe 150872 151965 151965 151895 152167 151966 152296 3 Tank cover with...

Page 4: ...ow or incorrect voltage Have a qualified electrician check house wiring Damaged Impeller Contact a Zoeller Service Station Incorrect float adjustment Contact Product Support Department Pump is air loc...

Page 5: ...er sharp objects do not puncture the pump unit Level the pump unit to within 3 mm 1 8 using hydraulic cement or similar material SK2589 STEP 3 ROUGH IN 1 Position the pump unit a minimum of 3 mm 1 8 f...

Page 6: ...out using a 44 mm 1 hole saw This is to ensure there is no leakage problems from inlets not in use When utilizing side inlets install a check valve on the incoming line SK2591 DRILL POINT 1 1 2 SLIP I...

Page 7: ...m 220 DN25 1 pipe max 149 m 489 DN20 pipe max 119 m 390 DN25 1 pipe max 218 m 715 DN20 pipe max 171 m 561 2 m 6 5 4 m 13 50 Hz 60 Hz 1 5 m 5 3 m 10 4 m 13 5 m 15 1 DN25 1 PIPE MAX 146m 479 DN20 3 4 P...

Page 8: ...Member States relating to Pump Conforms to Machinery Directive 2006 42 EC Standards used EN 809 1998 Electromagnetic Compatibility 2004 108 EC Standards used EN 61000 3 2 EN 61000 3 3 and EN 55014 1...