QWIK JON

®

 100/101/102/103 SYSTEMS

INSTALLATION INSTRUCTIONS

 1. 

To help reduce the risk of electrical shock

, a properly 

grounded receptacle or control box of grounding type must 

be installed and protected by a ground fault circuit interrupter 

(GFCI) in accordance with the National Electrical Code and 

applicable local codes. 

 Never remove ground pin from 

plug.

  If pump is wired direct, a GFCI must be installed in the 

control box. 

(SEE WARNING BELOW)

 2. Make certain that the ground fault interrupter protected 

receptacle or control box is within reach of the

 

pump’s power 

supply cord. 

DO NOT USE AN EXTENSION CORD

. Extension 

cords that are too long or too light do not deliver sufficient 

voltage to the pump motor. But more important, they could 

present a safety hazard if the insulation were to become 

damaged or the connection end were to fall into a damp or 

wet area.

 3. 

Make sure the pump's electrical supply circuit is equipped 

with fuses or circuit breakers of proper capacity.

 A separate 

branch circuit, sized according to the National Electrical Code 

for the current shown on the pump name plate is recommended.

 4.

  TESTING FOR GROUND.

 As a safety measure, each electrical 

outlet should be checked for ground using an Underwriters 

Laboratory Listed circuit analyzer which will indicate if the 

power, neutral and ground wires are correctly connected to 

your outlet. If they are not, call a qualified licensed electrician.

 

5.

  FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP 

FROM ITS POWER SOURCE BEFORE HANDLING.  If 

pump is wired direct, de-energize the circuit at the control 

box. 

 Grounded pumps are supplied with a 3-prong grounded 

plug to help protect you against the possibility of electrical 

shock. 

DO NOT UNDER ANY CIRCUMSTANCES REMOVE 

THE GROUND PIN.

 To reduce the risk of electrical shock, 

a properly grounded receptacle or control box of grounding 

type must be installed and protected by a ground fault circuit 

interrupter (GFCI) in accordance with national electrical code 

and applicable local codes.

 6.

 

Installation and checking of electrical circuits and hardware 

should only be performed by a qualified licensed electrician.

 7.

 

According to the state of California (Prop 65), this product 

contains chemicals known to the state of California to cause 

cancer and birth defects or other reproductive harm.

NOTICE TO INSTALLER:  Instructions must remain with installation.

SECTION:  6.10.067

FM1469

0413

Supersedes

1209

P/N 010536

PREINSTALLATION CHECKLIST

  1.  Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before 

using. 

Do Not

 remove the test plugs from the pump.                      

  2.  Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use before at

tempting 

the installation. These materials should be retained for future reference.                  

  1.  Check to be sure your power source is adequate to handle 

the amperage requirements of the motor as indicated on the 

pump or unit I.D. tag. 

  2. All plumbing (discharge and vent lines) must be installed 

to meet local codes. 

Unit must be vented. Do not use an 

automatic plumbing vent device. Toilet will not flush.

     

  3.  Maximum continuous operating temperature for models 100 

and 102 must not exceed 130°F (54°C).  Maximum continuous 

operating temperature for model 101 must not exceed 110°F 

(43°C).

                      

  1.  Repair and service should be performed by an Authorized 

Service Station only.  (Consult factory.)

  2. NOTE: Recommended for installations up to 13' (Models 

100/101) and 16' (Model 102) total dynamic head. Consult 

factory if installation is above 15' vertical height in 2" pipe. 

Sewage Pumps WM266, WM264 and WM211 are designed 

for use in Qwik Jon

®

 units only. They are not designed for 

use in any other application.

  3.  Do not use wax seal having flange that extends into tank; it 

may cause clogging. If a floor is installed over the tank, use 

a Zoeller designed floor flange extender seal kit (Included).

  4.  For installation below the original floor line, consult Factory. 

Patent No. 5,038,418

MODEL NO. _____________

DATE CODE: ____________

DATE INSTALLED: _______

U P C

®

C

SEE BELOW FOR LIST OF NOTES

NOTES

NOTE: Pumps with the “UL” mark and pumps with the “US” 

mark are tested to UL Standard UL778. CSA Certified pumps 

are certified to CSA Standard C22.2 No.108.

REfER TO WARRANTy ON pAgE 2.

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

Model 103 is not 

IAPMO approved.

Summary of Contents for QWIK JON 100

Page 1: ...efects or other reproductive harm NOTICE TO INSTALLER Instructions must remain with installation SECTION 6 10 067 FM1469 0413 Supersedes 1209 P N 010536 PREINSTALLATION CHECKLIST 1 Inspect all materia...

Page 2: ...Y AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Somestatesdonotallowlimitationsonthedurationofanimplied...

Page 3: ...19 Meters 15 10 5 Feet 4 6 3 0 1 5 MODEL Liters 276 148 72 27 67 105 19 2 ft 5 9m 102 254 397 40 78 110 295 151 416 Gal Liters Gal Liters 17 5 ft 5 3m WM264 WM266 MODEL 102 MODEL 100 MODEL 101 PUMP P...

Page 4: ...INSTALLATION OF THE CAST IRON SUPPORT Model 101 If the bolts are correct for your desired installation skip to STEP 6 NOTE If subflooring is being installed over the tank use the 20 X 3 long bolts sup...

Page 5: ...in Figure 6 1 The pump should not turn ON 6 4 Fill the tank with an additional of water The pump should turn ON before the water level reaches 4 Refer to the Troubleshooting Guide on page 11 for prob...

Page 6: ...RD SEAL NOTE INSTALL CORD SEAL BEFORE INSTALLING PIPE SEALS OVERLAP DETAIL TOP OF TANK GASKET AREA STEP 7 INSTALLATION OF LID AND ASSOCIATED PLUMBING NOTE STEPS 7 1 7 3 are for Models 100 102 only For...

Page 7: ...K1589 Check local codes for discharge and vent sizing and installation Figure 9 1 NOTE The bottom of the additional fixture 3 diameter hole must be 5 or 6 minimum above the base of the tank depending...

Page 8: ...BFLOOR 3 4 THICK MINIMUM 2X4 STUDS 2X6 FLOOR JOISTS VENT VENT GFCI DISCHARGE VENT 4 10 cm MIN NOTE 1 ALL VENTS AND DISCHARGE PIPING MUST BE INSTALLED ACCORDING TO LOCAL CODES 2 WALL BOARD REMOVED FOR...

Page 9: ...OR 3 4 THICK MINIMUM 2X4 STUDS 2X6 FLOOR JOISTS VENT VENT GFCI 4 10 cm MIN NOTE 1 ALL VENTS AND DISCHARGE PIPING MUST BE INSTALLED ACCORDING TO LOCAL CODES 2 WALL BOARD REMOVED FOR CLARITY TO SHOW PIP...

Page 10: ...ARGE PIPE TO ROOF VENT ACCORDING TO LOCAL CODES PIPING MUST BE INSTALLED NOTE ALL VENTS AND DISCHARGE 115V GROUND FAULT CIRCUIT INTERRUPTER GFCI DISCHARGE IF UNIT IS 230V THEN INSTALL GFCI 5 VERTICAL...

Page 11: ...009119 Float Bulb 1 SK1587 MODELS 100 D 101 A 102 E 103 A REF NO DESCRIPTION QTY WM264 10 97 to Present WM211 07 01 to Present WM266 10 97 to Present WD266 11 99 TO Current WM270 10 95 to Current WD27...

Page 12: ...terial has accumulated blocking flow of material Hold flush handle down on toilet for 15 seconds If unit will not clear unplug and wait 30 minutes Plug unit back in and repeat If unit still will not t...