OUTLET

PRIMARY PUMP

1" MIN.

IMPORTANT: OFF LEVEL 

OF FLOAT ASSEMBLY 

MUST BE HIGHER THAN 

DC BACKUP PUMP

FIG. 1

DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP

BATTERY BOX

AQUANOT KEY CONTROLLER

OUTLET

CONTROLLER

TYPICAL INSTALLATION

FIGURE 1

SK3260

Summary of Contents for ProPak AQUANOT KEY 507/73

Page 1: ...backuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off It is recommended that the pit be 18 45 7 cm in diameter or larger to accommodate both a primary and a DC backup pump 6 For indoor use only C...

Page 2: ... This warranty gives you specific legal rights and you may also have other rights which vary from state to state In instances where property damages are incurred as a result of an alleged product failure the property owner must retain possession of the product for investigation purpose 1 Electrical wiring and protection must be in accordance with National Electrical Code and any other applicable s...

Page 3: ... Battery Box Construction Non corrodible plastic Safety Snap tight lid keeps battery safe and clean When AC power is available the controller will replace the power used by the pump once the pump shuts off The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery after use when AC power is restored Time for recharge depends upon the...

Page 4: ...h After 1 second splash activation prevention delay the DC backup pump will run and the alarm will sound after 1 more second Lower the operational float switch after the alarm sounds Take care that the intake of the DC pump is set above the intake of the primary pump If water was pumped the Yellow DC Pump LED and alarm will remain on indicating that the pump ran and pumped water The alarm can be s...

Page 5: ...d 5 OUTLET PRIMARY PUMP 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT KEY CONTROLLER OUTLET CONTROLLER TYPICAL INSTALLATION FIGURE 1 SK3260 ...

Page 6: ...11 Hardware pak charger switch mode 1 152864 12 Power supply 1 157388 AQUANOT KEY FLOAT SWITCH SK3186 LOCKING PIN MUST BE INSTALLED UNDER FLOAT ROD INTHIS LOCATION MOLEX 2 PIN CONNECTOR MOLEX 4 PIN CONNECTOR SK3262 OPERATIONAL FLOAT DC PUMP LED TEST BUTTON BLACK LEAD NEGATIVE FLOAT STATUS LED SILENCE BUTTON WHITE LEAD POSITIVE AC POWER ADAPTER PORT 30 AMP FUSE DC PUMP SYSTEM READY LED BATTERY LED ...

Page 7: ...f required 6 Alarm sounds during battery recharge cycle a To silence alarm if alarm will not reset unplug the charger from 115 V wall outlet then disconnect the black lead from charger on negative battery post Check battery Replace if necessary Reconnect and refer to Installation Instructions To perform a Factory Reset hold the Silence and Test buttons together A Factory Reset restores all setting...

Page 8: ...ord label also describes LED and button functionality CARBON MONOXIDE DETECTORS Some battery types used in battery backup systems regardless of brand or manufacturer have the potential to give off gaseous by products when charging Some of these by products can produce a rotten egg odor Also some of these by products can cause a CO detector to falsely activate In order to help prevent false activat...