background image

© Copyright 2021 Zoeller

®

 Co. All rights reserved.

2

LIMITED WARRANTY

Manufacturer warrants, to the purchaser and subsequent owner during the 

warranty period, every new product to be free from defects in material and 

workmanship under normal use and service, when properly used and maintained, 

for a period of 3 years from date of purchase by the end user. Zoeller batteries 

have a 3 year warranty. Proof of purchase is required. Parts that fail within 

the warranty period, that inspections determine to be defective in material or 

workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit. No allowance 

will be made for shipping charges, damages, labor or other charges that may 

occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable 

act of nature; that has not been installed, operated or maintained in accordance 

with Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications. The warranty set out in the paragraph above is 

in lieu of all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in connection 

with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, Attention: 

Customer Support Department to obtain any needed repair or replacement of 

part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL 
OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; 
AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND 
OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED 
WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so 

the above limitation may not apply to you. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

    1.     Electrical wiring and protection must be in accordance with    National 

Electrical Code and any other applicable state and local electrical 

requirements.

  2.   All installations require a basin cover to prevent debris from falling into 

the basin and to prevent accidental injury.

  3.   Securely tape or clamp power cord to discharge pipe, clear of the float 

mechanism(s).

  4.  Use full-size discharge pipe.

  5.   Basin must be in accordance with applicable codes and specifications.

 

6.   Pump must be level and float mechanism(s) clear of sides of basin 

before starting pump.  Float switch may be repositioned as needed.

  7.  Basin must be clean and free of debris after installation.

  8.   Gate valve or ball valve to be supplied by installer and installed 

according to any and all codes.

  9.  Gas tight seals required to contain gases and odors.

  10.   Vent gases and odors to the atmosphere through vent pipe.

  11.    Install Zoeller Pump Stand (Model 10-2421) under pump to 

 

  provide space for settling dirt, sand, or grit".

RECOMMENDED INSTALLATION FOR ALL APPLICATIONS

EASY DO'S & DON'TS FOR INSTALLING A SUMP PUMP

   1.  DO read thoroughly all installation material provided with the system.

   2.  DO inspect system for any visible damage caused by shipping.  Contact dealer 

if system appears to be damaged.

   3.  DO clean all debris from the sump.  Be sure that the pump will have a hard, 

flat surface beneath it.  DO NOT install on sand, gravel or dirt.

   4.  DO be sure that the sump is large enough to allow proper clearance for the 

level control switch(es) to operate properly.

   5.  DO always disconnect pump from power source before handling.

  6.  DO always connect to a separately protected and properly grounded circuit.

  7.  DO NOT ever cut, splice, or damage power cord (only splice in a watertight 

junction box).

  8.  DO NOT carry or lift pump by its power cord.

  9.  DO NOT use an extension cord with a sump pump.

   10.  DO  install a union in the discharge line.

  11.  DO  NOT use a discharge pipe smaller than the pump discharge.

  12.  DO  NOT use a sump pump as a trench or excavation pump, or for pumping 

sewage, gasoline, or other hazardous liquids.

 13. DO  test system immediately after installation to be sure that the system is 

working properly.

  14.  DO  cover sump with an adequate sump cover.

  15.  DO  review all applicable local and national codes and verify that the installation 

conforms to each of them.

  16.  DO  consult manufacturer for clarifications or questions.

   17.  DO  inspect and test system for proper operations at least every three months.

Summary of Contents for ProPak AQUANOT KEY 507/73

Page 1: ...backuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and is secured so the pump will turn on and off It is recommended that the pit be 18 45 7 cm in diameter or larger to accommodate both a primary and a DC backup pump 6 For indoor use only C...

Page 2: ... This warranty gives you specific legal rights and you may also have other rights which vary from state to state In instances where property damages are incurred as a result of an alleged product failure the property owner must retain possession of the product for investigation purpose 1 Electrical wiring and protection must be in accordance with National Electrical Code and any other applicable s...

Page 3: ... Battery Box Construction Non corrodible plastic Safety Snap tight lid keeps battery safe and clean When AC power is available the controller will replace the power used by the pump once the pump shuts off The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery after use when AC power is restored Time for recharge depends upon the...

Page 4: ...h After 1 second splash activation prevention delay the DC backup pump will run and the alarm will sound after 1 more second Lower the operational float switch after the alarm sounds Take care that the intake of the DC pump is set above the intake of the primary pump If water was pumped the Yellow DC Pump LED and alarm will remain on indicating that the pump ran and pumped water The alarm can be s...

Page 5: ...d 5 OUTLET PRIMARY PUMP 1 MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT KEY CONTROLLER OUTLET CONTROLLER TYPICAL INSTALLATION FIGURE 1 SK3260 ...

Page 6: ...11 Hardware pak charger switch mode 1 152864 12 Power supply 1 157388 AQUANOT KEY FLOAT SWITCH SK3186 LOCKING PIN MUST BE INSTALLED UNDER FLOAT ROD INTHIS LOCATION MOLEX 2 PIN CONNECTOR MOLEX 4 PIN CONNECTOR SK3262 OPERATIONAL FLOAT DC PUMP LED TEST BUTTON BLACK LEAD NEGATIVE FLOAT STATUS LED SILENCE BUTTON WHITE LEAD POSITIVE AC POWER ADAPTER PORT 30 AMP FUSE DC PUMP SYSTEM READY LED BATTERY LED ...

Page 7: ...f required 6 Alarm sounds during battery recharge cycle a To silence alarm if alarm will not reset unplug the charger from 115 V wall outlet then disconnect the black lead from charger on negative battery post Check battery Replace if necessary Reconnect and refer to Installation Instructions To perform a Factory Reset hold the Silence and Test buttons together A Factory Reset restores all setting...

Page 8: ...ord label also describes LED and button functionality CARBON MONOXIDE DETECTORS Some battery types used in battery backup systems regardless of brand or manufacturer have the potential to give off gaseous by products when charging Some of these by products can produce a rotten egg odor Also some of these by products can cause a CO detector to falsely activate In order to help prevent false activat...