background image

9

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

PUMP WIRING INSTRUCTIONS, continued

016889

016890

SINGLE PHASE AUTOMATIC

MODEL X282

FLOAT 

SWITCH
COM

NC

1

2

3

4

R

RELAY

4

6

0

1

R

2

6

4

5

GE RELAY

SEAL FAILURE PROBES 

BLA

CK 

OR 

WHITE/BLA

CK TR

ACER

BLA

CK 

OR 

WHITE/BLA

CK TR

ACER

MOTOR

AUXILIARY WINDING

MAIN WINDING

OVERLOAD

YELL

OW

RED

BL

UE

POWER CORD

M1

M1

M2

M2

RED

GREEN

3

3

RED

BL

UE

2

2

1

1

CAPACITOR

OR

ANGE

WHITE

BLA

CK

330K OHMS RESISTANCE

YELL

OW

BLACK

BLUE

BLACK
OR

WHITE

CONNEC

T RED AND OR

ANGE LEADS 

TO 

OPTIONAL SEAL F

AIL P

ANEL (10-1031) 

TO ENABLE MOISTURE SENSOR CIR

CUIT 

IF REQUIRED B

Y L

OC

AL C

ODES.

SINGLE PHASE AUTOMATIC

MODELS X160 - X290

Summary of Contents for MX161

Page 1: ...63 X165 X185 X186 X188 X189 X191 ZOELLER HAZARDOUS LOCATION PUMPS Class I Division I Groups C D and Class 1 Zone 1 Groups IIA IIB Gas Areas OR Class II Division I Groups E F G and Zone 20 Dust Areas M...

Page 2: ...tomintake design to reduce clogging and seal failures If a check valve is incorporated in the installation a vent hole approx 3 16 must be drilled in the discharge pipe below the check valve and pit c...

Page 3: ...450 200 1 60 12 6 6 1 26 8 F 2 0 1 8 JX165 1 3450 200 3 60 7 5 4 8 31 1 M 3 6 3 2 FX165 1 3450 230 3 60 7 4 3 8 29 8 N 5 5 4 7 GX165 1 3450 460 3 60 3 7 2 1 14 9 N 21 8 19 0 BAX165 1 3450 575 3 60 3 0...

Page 4: ...AX292 1 2 3450 575 3 60 2 4 1 7 11 3 U 38 0 33 0 DX293 1 3450 230 1 60 10 2 6 6 20 1 E EX293 1 3450 230 1 60 10 2 6 6 20 1 E 3 0 2 6 HX293 1 3450 200 1 60 12 0 7 5 26 8 F IX293 1 3450 200 1 60 12 0 7...

Page 5: ...structionsareincludedwiththerailsystem and basin instructions If pump is being retrofitted to an existing rail system accessory parts may be required Consult the factory and advise make and model of r...

Page 6: ...6 4 2 0 10 5 10 20 15 20 FLOW PER MINUTE 110 160 240 320 400 30 40 50 60 70 80 100 90 X282 560 480 640 150 130 120 140 X292 170 160 180 X284 80 14 12 10 8 TOTAL DYNAMIC HEAD 25 30 35 40 45 22 20 18 16...

Page 7: ...ILABLE 8 9 16 217 mm 1 1 2 NPT CONDUIT CONNECTION 24 15 16 21 1 2 4 29 32 125 mm 6 1 16 154 mm 116 mm 222 mm 165 mm 633 mm 546 mm 4 9 16 116 mm SK2506 5 127 mm 8 9 16 217 mm 6 5 16 160 mm 2 NPT OR 3 N...

Page 8: ...or strain relief Installation and checking of electrical circuits and hardware should be performed by a qualified licensed electrician EXPLOSION PROOF WIRING DIAGRAMS X160 X180 X190 X280 X290 X400 SE...

Page 9: ...ACK OR WHITE BLACK TRACER BLACK OR WHITE BLACK TRACER MOTOR AUXILIARYWINDING MAINWINDING OVERLOAD YELLOW RED BLUE POWER CORD M1 M1 M2 M2 RED GREEN 3 3 RED BLUE 2 2 1 1 CAPACITOR ORANGE WHITE BLACK 330...

Page 10: ...and switch any two power leads Turn power back on and retest for proper rotation SENSOR WIRES See pages 8 and 9 The power and sensor wires are contained in the same cord The green wire is a ground con...

Page 11: ...properly sealed After installing the pump into the containment area with adequate submergence open the discharge valve fully Start the unit using manual controls If flow is appreciably less than rate...

Page 12: ...age thermal overload open impeller clogged float switch held down or defective incorrect wiring in control panel water in cap assembly Incorrect voltage impeller blocked negativehead dischargelowertha...

Reviews: