background image

HOW TO INSTALL

JACKEL’S 4" DWV SNAP-IN HUB*

Note: 

The Snap-in hub is made from plastic rubber and is designed for use 

with 4" DWV ABS Schedule 40 pipe and 4" PVC Schedule 40 pipe (4-1/2"  

O.D.) and has an operating range from -28 °C (-20 °F) to 50 °C (120 °F).

(A) Step 1

Hold Snap-in hub in upward position in right hand so that the 

ARROW and TOP markings are visible.

Step 2

With right hand push bottom track, which is molded in the Snap-

in hub, into the bottom edge of tank hole.

Step 3

Hole in place with left hand inside tank. Then squeeze hub 

outside of tank into oval shape and push into hole, pulling with 

left hand and fitting rest of hole edge into the track.

Step 4

If hub appears out of round, run fingers around inside hub seal to 

make sure it has a tight fit. Examine outer lip edge and press into 

track if caught on outer edge.

(B)

To insert your 4" ABS or PVC pipe:

Step 1

Cut pipe square.

Step 2

Chamfer end. Failure to do so can cut built-in ‘O’ rings off. 

The ‘O’ rings in the Snap-in hub make the seal and are vital.

Step 3

USE ANY LIQUID SOAP and rub around the circumference of the 

pipe approximately 102 mm (4") back from the chamfered end and

insert chamfered end of pipe into the Snap-in hub using sufficient 

pressure to push pipe through the Snap-in hub. Extend pipe into 

tank approximately 25 mm (1") beyond the inside edge of the snap-

in hub.

Caution:

 DO NOT USE A TWISTING FORCE – rather, use a 

sideways motion.

Step 4

Install non-corrosive clamp by placing the worm gear housing of 

clamp in slot provided on the top of the Snap-in hub. Wrap strap 

around inside the groove and tighten sufficiently.
Note: Snap-in hub is not mechanically sealed. 

*Patent Applied For

Form No. 821711

Jackel. lnc./1982

       Snap-in Hub

INSTALLATION INSTRUCTIONS

- 15  - 

© Copyright 2019 Zoeller   Co. All rights reserved.

®

Summary of Contents for 910

Page 1: ...maged it must be replaced by an authorized Zoeller Representative 9 Pump may contain oil which becomes pressurized and hot when operating Allow 2 1 2 hours after disconnecting before attempting servic...

Page 2: ...onsult the factory Do not attempt to service or otherwise disassemble pump Service must be performed by an authorized Zoeller Company representative SERVICE CHECKLIST EASY DO S DON T S FOR INSTALLING...

Page 3: ...ions with warranty after installation This product must be installed in accordance with National Electric Code ANSI NFPA 70 so as to prevent moisture from entering or accumulating within boxes conduit...

Page 4: ...N COVER AND CLEANED PERIODICALLY High Head unit see 3 under Caution on front page Water stream will be visible from this hole during pump run periods mechanism s Use full size discharge pipe Basin mus...

Page 5: ...nnection Check valve Ball valve Inlet hub 2 Pipe 2 Pipe Union 600 mm 23 19 32 Length 90 mm 3 1 2 Coupling Length 200 mm 7 7 8 For reference only 2 BSPT slip 2 NPT slip or 2 Pipe 2 BSPT slip 2 NPT slip...

Page 6: ...pe seal Vent adaptor Discharge pipe seal Cord seal For alarm 2 Union Check valve 2 turn DN50 Length 90 mm 3 1 2 Length 762 mm 30 DN100 2 NPT slip x 2 or 1 1 4 NPT slip x 1 Inlet hub Discharge pipe sea...

Page 7: ...ailure to follow these precautions could result in serious injury or death Replace product immediately if switch cable becomes damaged or severed Keep these instructions with warranty after installati...

Page 8: ...ge as shown in Figure A Pumping range can be adjusted by moving the float stop up or down the rod 2 Insert hose clamp through slots in mounting bracket as shown in Figure B 3 Position hose clamp aroun...

Page 9: ...OTE THE HOLE MUST ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY High Head unit see 3 under Caution on front page Water stream will be visible from this hole during pump run periods mechanism...

Page 10: ...ights reserved Union Pipe DN50pipe DN50 550 mm 21 21 32 STEP 3 Check valve Ball valve 1 1 2 BSPT x 1 1 2 slip 1 1 2 Pipe 1 1 2 Pipe Union Pipe DN40 1 1 2 Pipe 13 8 2 11 9 EA0054 Vent adaptor TYPICAL D...

Page 11: ...seal Discharge pipe seal With thread Cord seal 2 orDN50 Union Check valve Grinder only Grinder only Grinder only 2 turn DN50 Length 90 mm 3 1 2 Length 762 mm 30 DN100 Inlet hub 2 BSPT x 2 slip or 2 N...

Page 12: ...drill the 5 mm hole Location to fix the float 4 Basin 460x760 mm 1 2 3 4 5 Electrical wiring and protection must be in accordance with governing electrical code and any other applicable local electri...

Page 13: ...EA0055 Basin 460x760 mm 1 2 3 4 5 Electrical wiring and protection must be in accordance with governing electrical code and any other applicable local electrical requirements Install proper Zoeller un...

Page 14: ...valve Ball valve Coupling 2 Pipe Union 13 8 2 11 9 Pump diagram for reference only EA0055 TYPICAL DEWATERING INSTALLATION Turn Top logo upward DN100Pipe RECOMMENDED INSTALLATION FOR ALL APPLICATIONS...

Page 15: ...into track if caught on outer edge B To insert your 4 ABS or PVC pipe Step 1 Cut pipe square Step 2 Chamfer end Failure to do so can cut built in O rings off The O rings in the Snap in hub make the s...

Page 16: ...0 mm DIMENSIONAL DATA A D SK2903 C B SK2694 A D C B 673 mm A B C Size Dimensions 24 x 24 26 1 2 651 mm 25 5 8 203 mm 8 711 mm 28 520 mm 20 1 2 560 mm 22 1 16 241 mm 9 1 2 406 mm 16 552 mm 21 3 4 762 m...

Page 17: ...E BELOW THE BASIN COVER AND CLEANED PERIODICALLY High Head unit see 4 under Caution on front page Water stream will be visible from this hole when pump is operating 5 mechanism s 6 Use full size disch...

Page 18: ...in accordance with all applicable local codes and ordinances All three phase pumps require motor starting devices with motor overload protection Three phase pumps must be installed in accordance with...

Page 19: ...RATION OF CONFORMITY We Zoeller declare under our sole responsibility that the models 49 53 55 57 59 72 76 86 88 98 137 139 140 4140 145 4145 152 153 161 162 163 165 185 189 222 264 266 267 268 270 42...

Page 20: ...3 161 162 163 165 185 189 371 372 373 222 264 266 267 268 270 4270 271 4271 282 292 293 294 4290 4291 422 807 2702 2722 1 2 3 20 2019 Zoeller 1 8 5 7 130 54 104 2 3 4 6 5 2 11 8 7 10 5 mm 6 9 1 2 3 4...

Page 21: ...1 4 2 3 5 6 8 9 7 10 11 4 12 13 3 14 21 1 5 5 1 2 3 4 A D Zoeller F G E B C 2019 Zoeller...

Page 22: ...610x610mm 2 1 1 4 2 1 1 4 1 1 4 2 2 or DN50 2 x16 2 or DN50 BSPT NPT BSPT 2 DN50 90 mm 170 mm 200 mm 375 mm x2 22 2019 Zoeller 1 1 3 1 90 mm 90 mm 2 1 EA0053...

Page 23: ...5 6 14 4 7 9 260 mm 3 13 12 23 2019 Zoeller 5 mm 45 180 2 375 mm 1 2 3 4 6 7 8 9 10 11 12 13 14 5 1 2 EA0053 EA0053 5mm 4 610x610mm...

Page 24: ...24 2019 Zoeller 3 EA0053 610x610 mm 2 2 2 1 1 4 1 1 4 2 1 1 4 BSPT NPT BSPT NPT BSPT NPT 2 600 mm 90 mm 200 mm or DN50 DN50 DN100...

Page 25: ...m 1 1 2 2 orDN50 2 NPT or BSPT x4 2 orDN50 2 90 mm 762 mm x3 DN100 EA0054 1 1 2 BSPT x4 1 1 2 1 1 2 1 1 2 90mm 762 mm x3 DN100 2 DN50 2 DN50 2 DN50 2 2 1 1 4 NPT x4 2 2 90 mm 762 mm x3 DN100 2 DN50 1...

Page 26: ...26 EA0095 U S Patent No 5 155 311 Canadian Patent No 2 060 748 20 170 mm 52 C 125 F 2019 Zoeller...

Page 27: ...27 A C B 1 2 3 4 1 5 A 1 2 3 1 5 230 230 90 mm 260 mm 320 mm 2019 Zoeller A 1 2 3 4 5 B A...

Page 28: ...460x560 mm 5 6 14 4 7 9 90 mm 260 mm 320 mm 13 3 12 12 12 28 2019 Zoeller 1 2 EA0054 EA0054 5 mm 4 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...

Page 29: ...13 460x560 mm 29 2019 Zoeller 3 EA0054 DN100 DN50 2 2 DN50 DN50 DN50 1 1 2 1 1 2 1 1 2 550 mm Top 2 8 2 11 9 or 2 1 1 4 1 1 4 2 1 1 4...

Page 30: ...30 2019 Zoeller 460x760 mm 2 2 or DN50 2 x8 x6 2 or DN50 x3 NPT NPTorBSPT 90 mm 762 mm DN100 EA0055 1 1 4 2 1 1 4 170 mm 2 1 1 4 NPT 2 DN50...

Page 31: ...31 2019 Zoeller 460x760 mm 2 5 6 4 7 9 1 2 EA0055 EA0055 5 mm 4 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...

Page 32: ...32 2019 Zoeller 3 13 3 12 12 12 EA0055 460x760 mm 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...

Page 33: ...460x760 mm 33 2019 Zoeller 4 2 2 13 8 2 11 9 550 mm EA0055 Top DN100 DN50 2 2 1 1 4 1 1 4 2 1 1 4 DN50 DN50...

Page 34: ...4 DWV ABS Sch40 4 PVC Sch40 4 1 2 20 120 TOP A B 4 ABS PVC O Ring O Ring 4 1 2019 Zoeller 34...

Page 35: ...35 2019 Zoeller SK2694 A D C B 673 203 711 520 560 241 651 A B C D 460 x 560 552 762 267 406 419 460 x 760 610 x 610 460x560 mm 460x760 mm A D SK2903 C B 610x610 mm mm...

Page 36: ...2019 Zoeller 10 30 0164 50 mm 1 1 2 30 0152 63 mm 2 30 0160 90 mm 3 5 mm 4 180 10 2421 FM1597 FM0531 FM0732 FM1420 457mmX610 mm 100 mm 100 mm AC U F 3 3 3 3 1 2 3 13 8 7 11 5 4 12 12 9 10 6 1 2 3 7 9...

Page 37: ...SK1217 SK1218 37 2019 Zoeller FM0526 PVC 10 1457 3 3 L1 L2 1 2 L3 013071 006848 20 P N 10 0748...

Page 38: ...V WU 220 V 1 Ph 50 Hz 5 10 15 20 22 9 13 5 18 22 24 1 2 L1 L2 3 011835 20 WU SK305 38 2019 Zoeller V WU 1 25 5 22 WU a b c 1 2 3 4 EA0047 2 2 2 1 1 1 P N 10 1494 50 mm...

Reviews: