CARBON MONOXIDE DETECTORS

Whether you have a “Basement Sentry

®

” Backup Pump System, or a competitive brand, all use batteries that give off gaseous by-products when charging. 

Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent 

false activation, Zoeller Company recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior. 

Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede 

the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer.

If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1)  Take immediate action for personal safety as recommended in the CO detector literature.

2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.

3)  If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to 

activate. Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation.

MAIL TO:

  P.O. 

BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

Your Peace of Mind is Our Top Priority

 

®

®

visit our web site:

www.zoeller.com

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged 

and may damage the charging circuits of the Control. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/Acid Deep-Cycle 

Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours.  These times are based on continuous pumping at 10' of 

static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger.

•  Do NOT use a “maintenance-free” battery unless it is a Gel-filled or AGM battery.

•  Replace your battery every 3 years.

•  Do not let corrosion build up on the battery terminals.

•  To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries).

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (not applicable for gel or AGM batteries).

THE AQUANOT

®

 

BATTERY

Summary of Contents for 507-0005

Page 1: ...state of California to cause cancer and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must b...

Page 2: ...chased and used as a backup to a primary dewatering system A complete system includes a Model 507 Basement Sentry and an Aquanot Battery 1 Inspectandtestthesystemforproperoperationsatleastevery3months...

Page 3: ...e DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installatio...

Page 4: ...DC pump and measure between the in line check valve and tee Use that measurement to cut discharge pipe Solvent weld that piece first to the tee Measure cut solvent weld any remaining discharge piping...

Page 5: ...PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS BATTERY BOX BATTERY BOX OUTLET PRIMARY PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN SK2499 SK25...

Page 6: ...SUPPLIED BY USER DC BACK UP PUMP CLAMP FLOAT SWITCH WHITE LEAD TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE 15 AMP FUSE DC CHARGER BLACK LEAD TO NEGATIVE TO FLOAT S...

Page 7: ...D will always display the battery voltage and current going to the battery if charging The alarm screen shows current alarms The cycle counter screen shows how many times the DC float has been activat...

Page 8: ...the CO detector to activate Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Can...

Reviews: