3
© Copyright 2014 Zoeller Co. All rights reserved.
MODELS:
507-C
507-D
507-E
507-F
ITEM DESCRIPTION
QTY
4/96
thru
10/05
11/05
thru
9/11
10/11
thru
10/13
11/13
thru
Current
1
DC backup pump
1
010475
017198
017198
017198
2
Plastic battery box and cover
1
10-0764
10-0764
10-0764
10-0764
3
DC control charger with terminals
1
152899
152899
152899
152899
4
“Off”/”On” float switch
1
017197
017197
017197
017197
5
1½" x 5" long PVC pipe nipple
1
005639
N/A
N/A
N/A
6
Check valve
(2) REV C - (1) REV D
005636
005636
019768
019768
7
Reducer hose coupling and clamp
1
30-0188
N/A
N/A
N/A
8
1¼" x 1" PVC reducer fitting
1
005642
N/A
N/A
N/A
9
1" pipe to hose adapter elbow
1
005643
N/A
N/A
N/A
10
1" hose coupling and two clamps
1
005703
N/A
N/A
N/A
11
1½" PVC pipe tee
1
005645
005645
005645
005645
12
1½" 90 degree PVC pipe elbow
1
005644
N/A
N/A
N/A
13
1¼" x 1¼" PVC coupling
1
009129
N/A
N/A
N/A
14
Pump mounting kit, includes brkt, S.S. worm drive
clamp, two #10-24 screws and washers.
1
005704
N/A
N/A
N/A
15
Cable tie
1
005868
N/A
N/A
N/A
16
Anchors, wall
2
009691
009691
009691
N/A
17
Bracket, control mounting
1
007779
007779
007779
N/A
18
1½" x 1½" PVC coupling
1
N/A
009746
N/A
N/A
19
Clamp, H28 SS / zinc-plated screw
1
012724
012724
012724
012724
20
Fuse, AGC - 15 amp
1
N/A
012352
012352
012352
REPLACEMENT PARTS LIST
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The
DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system
is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.
DESCRIPTION
TROUBLESHOOTING INFORMATION,
continued
7. Alarm sounds during battery recharge cycle.
(a) Push alarm reset (max. 3 times). If condition persists, replace battery.
(b) To silence alarm if alarm will not reset, unplug the charger from
115V wall outlet, then disconnect the black lead from charger on
negative (-) battery post. Check battery. Replace if necessary.
Reconnect and refer to Installation (step 12).
2
12 VOLT BATTERY
SUPPLIED BY USER
1
19
4
20
3
6
11
SK2981
The DC emergency pump system requires a good quality, 12 volt
battery to obtain maximum pumping time during a power outage.
A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is
recommended and will provide approximately 7½ hours of continuous
pumping time in a sump pump installation with 8' of head pressure. In
most installations the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended
for ease of installation. These batteries contain acid and proper
precaution must be taken when handling. Maximum battery size
13½" length x 7" width x 9½" height.
BATTERY SELECTION