background image

12

13

IL1374

Wire from 

motor

4

IL1373

Wire from 

motor

3

IL1372

2

3.  Thread the cable from the pump motor 

through the strain relief into the pressure 

switch cavity and tighten both screws on the 

strain relief. Do not crush wire. 

4.  Connect the two motor wires of the motor 

cable to the two inside terminals on the 

pressure switch. 

2.   Insert an electrical wire strain relief into the 

opening in the side of the pressure switch 

closest to the motor.

IL1375

Wire from 

motor

Ground Screws

5

5.   Connect the green ground wire from the 

motor cable to one of the green ground 

screws at the bottom of the pressure switch.

Wire from 

motor

Wire from 

power

supply

7

IL1376

Wire from 

motor

Pressure

switch

Strain

relief

6

6.   Insert an electrical wire strain relief into the 

opening in the opposite side of the pressure 

switch.

7.  Thread the cable from the power supply 

through the strain relief and tighten both 

screws on the strain relief. Do not crush wire. 

Wire 

from 

motor

Wire from 

power

supply

Ground Screws

Green 

ground 

wire

9

Outside

terminal

Two wires 

from power 

supply

Outside

terminal

Wire from 

motor

Wire from 

power

supply

8

9.   Connect the green ground wire from the 

power supply to the remaining green ground 

screw in the pressure switch and re-attach 

the pressure switch cover. 

8.   Connect the two wires from the power supply 

to the two outside terminals on the pressure 

switch. 

Summary of Contents for 1461-0006

Page 1: ...hase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller...

Page 2: ...read and understand this entire manual before attempting to assemble operate or install the product NOTE Pumps with the UL Mark and pumps with the US mark are tested to UL Standard UL778 CSA certifie...

Page 3: ...ls or with cisterns or lakes Description Quantity Pump 1 PREPARATION Before beginning installation of product make sure all parts are present If any part is missing or damaged do not attempt to assemb...

Page 4: ...nufacturer Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION Use pipe tape and pipe paste compound on all male threads Tighten with wr...

Page 5: ...ssure gauge to ensure it s set to 18 PSI a Use a tire pump to adjust the PSI to 18 PSI b If water leaks from the air release valve replace the pressure tank CHECK TANK PRESSURE 20 20 20 20 Breaker Box...

Page 6: ...come in contact with oil grease hot surfaces or chemicals The pump must be properly grounded using the proper wire cable with ground CAUTION Protect the power cable from coming in contact with sharp o...

Page 7: ...of the pressure switch Wire from motor Wire from power supply 7 IL1376 Wire from motor Pressure switch Strain relief 6 6 Insert an electrical wire strain relief into the opening in the opposite side...

Page 8: ...nomical to run and requires a smaller wire size NOTE This pump is pre wired at the factory to run on 115 V A B L1 L2 IL1356 230V GRAY RED 2b A B L1 L2 IL1355 GRAY RED 2a b Pull the red wire with the f...

Page 9: ...eaker box and check all pipe connections for leaks All connections must be water and air tight in order for pump to operate All piping from the well to the pump should slope slightly upward with no sa...

Page 10: ...has been determined Please review the following troubleshooting questions before returning a pump as defective If you have any questions please call Customer Service at 800 584 8089 MODEL LIQUID PUMP...

Page 11: ...his warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXP...

Reviews: