12
13
IL1374
Wire from
motor
4
IL1373
Wire from
motor
3
IL1372
2
3. Thread the cable from the pump motor
through the strain relief into the pressure
switch cavity and tighten both screws on the
strain relief. Do not crush wire.
4. Connect the two motor wires of the motor
cable to the two inside terminals on the
pressure switch.
2. Insert an electrical wire strain relief into the
opening in the side of the pressure switch
closest to the motor.
IL1375
Wire from
motor
Ground Screws
5
5. Connect the green ground wire from the
motor cable to one of the green ground
screws at the bottom of the pressure switch.
Wire from
motor
Wire from
power
supply
7
IL1376
Wire from
motor
Pressure
switch
Strain
relief
6
6. Insert an electrical wire strain relief into the
opening in the opposite side of the pressure
switch.
7. Thread the cable from the power supply
through the strain relief and tighten both
screws on the strain relief. Do not crush wire.
Wire
from
motor
Wire from
power
supply
Ground Screws
Green
ground
wire
9
Outside
terminal
Two wires
from power
supply
Outside
terminal
Wire from
motor
Wire from
power
supply
8
9. Connect the green ground wire from the
power supply to the remaining green ground
screw in the pressure switch and re-attach
the pressure switch cover.
8. Connect the two wires from the power supply
to the two outside terminals on the pressure
switch.