Tire gauge

Tank

Air Valve/Stem

6

IL1369 

Glue

To House

Plumbing

From Pump

Shut off valve

Reducer 

Bushing

5

Glue

Tee

Union

1 in. pipe

4

5.   Attach the pipe from the pump to the tee 

installed in Step 4. Then, from the tee, 

install 1 in. pipe and optional shut off valve 

(not included) to connect tee to house 

plumbing. 1 x 3/4 in reducer bushing may 

be required to connect to house plumbing. 

6.   

IMPORTANT: 

Air pressure in the tank 

must be 2 PSI lower than the “cut-in” of 

the pressure switch. Pump has a 20/40 

PSI pressure switch, so tank pressure 

must be set at 18 PSI. Locate the air 

valve/stem on the tank and check 

pressure with a tire gauge (not included). 

If air needs to be removed, press down on 

valve to bleed off air. Use a tire pump or 

air compressor to add air if needed.

4.   Attach a 1 in. pipe (not included) to the 

reducer bushing. Install an optional 1 in. 

union (not included) and continue with pipe 

and 1 in. x 1 in. x 1 in. tee (not included).

  

WARNING

:  

•  Always disconnect pump from electricity 

before performing any work on the motor.

•  Under-sized wiring can cause motor failure 

and even fire. Use proper wire size specified 

in the Wire Size Chart.

•  Replace damaged or worn wiring cord 

immediately.

•  Do not kink power cable and never allow the 

cable to come in contact with oil, grease, hot 

surfaces, or chemicals.

•  The pump must be properly grounded using 

the proper wire cable with ground.

  CAUTION:  

•  Protect the power cable from coming in 

contact with sharp objects.

• 

All wiring should be performed by a qualified 

electrician in accordance with the National 

Electric Code and local electric codes.

•  Connect the pump to a separate electrical 

circuit with a dedicated circuit breaker. Refer 

to the Wire Size Chart for proper fuse size.

PUMP ELECTRICAL CONNECTIONS

WIRE SIZE CHART

Distance 

from Motor to 

Meter

Recommended Copper 

Wire and Fuse Sizes
Single Phase Motors

3/4 HP

115 Volt

230 Volt

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

200-300 Ft.

Fuse Size 

(Amps)

14

10

8

8

6

15

14

14

14

14

12

15

L1

L2

A

B

L1

L2

A

B

115 Volts

Single Phase

Line

230 Volts

Single Phase

Line

Y
E
L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Y
E
L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Check Voltage of Power Source

Before Connecting

DO NOT CONNECT ANY GROUND WIRE 

TO THESE LEADS

WIRING DIAGRAM

IL1380

Pressure

Switch

1

Wiring the Pressure Switch: 

CAUTION: Make certain that the power source 

matches the pump requirements. This pump has 

a dual voltage motor and can run on 115 V or 

230 V. This pump is pre-wired at the factory to 

run on 115 V.

NOTE: To change pump voltage, see wiring 

diagram on this page or instructions on page 14.

1.   Screw the pressure switch into the 1/4 in. 

opening on the top of the pump and remove 

the switch cover.

Summary of Contents for 1461-0006

Page 1: ...hase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller...

Page 2: ...read and understand this entire manual before attempting to assemble operate or install the product NOTE Pumps with the UL Mark and pumps with the US mark are tested to UL Standard UL778 CSA certifie...

Page 3: ...ls or with cisterns or lakes Description Quantity Pump 1 PREPARATION Before beginning installation of product make sure all parts are present If any part is missing or damaged do not attempt to assemb...

Page 4: ...nufacturer Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings CAUTION Use pipe tape and pipe paste compound on all male threads Tighten with wr...

Page 5: ...ssure gauge to ensure it s set to 18 PSI a Use a tire pump to adjust the PSI to 18 PSI b If water leaks from the air release valve replace the pressure tank CHECK TANK PRESSURE 20 20 20 20 Breaker Box...

Page 6: ...come in contact with oil grease hot surfaces or chemicals The pump must be properly grounded using the proper wire cable with ground CAUTION Protect the power cable from coming in contact with sharp o...

Page 7: ...of the pressure switch Wire from motor Wire from power supply 7 IL1376 Wire from motor Pressure switch Strain relief 6 6 Insert an electrical wire strain relief into the opening in the opposite side...

Page 8: ...nomical to run and requires a smaller wire size NOTE This pump is pre wired at the factory to run on 115 V A B L1 L2 IL1356 230V GRAY RED 2b A B L1 L2 IL1355 GRAY RED 2a b Pull the red wire with the f...

Page 9: ...eaker box and check all pipe connections for leaks All connections must be water and air tight in order for pump to operate All piping from the well to the pump should slope slightly upward with no sa...

Page 10: ...has been determined Please review the following troubleshooting questions before returning a pump as defective If you have any questions please call Customer Service at 800 584 8089 MODEL LIQUID PUMP...

Page 11: ...his warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXP...

Reviews: