INSTALLATION INSTRUCTIONS

4

5

6

4.  Place the pump inside the basin with the switch 

positioned away from incoming water.

5.  Be sure the fl oat switch is at least 1 in. away from the 

side walls of the basin and free of any obstructions 

through the full range of switch motion.

6.  Install rigid 2 in. discharge pipe (not included) according 

to local, regional, and state codes.

Incoming

water

Switch

Switch

1 in.

Minimum

Discharge

Pipe

Summary of Contents for 1263-0001Q

Page 1: ...istered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1316 B ZoellerAtHome com MODEL 1263 0001Q SEWAGE PUMP ZoellerAtHome com ...

Page 2: ...RISK OF ELECTRIC SHOCK These pumps have not been investigated for use in swimming pool areas WARNING 2 2020 All rights reserved Please read and understand this entire manual before attempting to assemble operate or install the product NOTE Pumps with the UL Mark and pumps with the US mark are tested to UL Standard UL778 CSA certified pumps are certified to CSA Standard C22 2 No 108 CUS ELECTRICAL ...

Page 3: ...list If any part is missing or damaged do not attempt to assemble the product Estimated Installation Time 2 hours Tools Required for Assembly not included Adjustable wrench hacksaw flathead screwdriver Phillips screwdriver tape measure utility knife pipe wrench Description Quantity Pump 1 PREPARATION Parts Required For Assembly not included sewage pump basin minimum 18 in w x 30 in deep basin cove...

Page 4: ...harge pipe Upper level drainage Cleanout Flange Lavatory 45 Elbow 2 in Check valve 2 in gate valve Union Vent pipe Sink Main waste line to sewer or septic tank Switch Pump Vent hole 1 2 These pumps are equipped with a float switch The pump will turn on automatically when the water level in the basin reaches the on level On 2 Off 3 Item On Level Off Level 1263 10 25 in 5 in 3 The pump will turn off ...

Page 5: ...IONS 30 in 18 in 1 Use a basin not included that is at least 18 in wide by 30 in deep 1 2 Clean the basin of all debris 2 3 Set the pump on a solid level surface A brick or block not included may be installed under the pump to provide a solid base 3 ...

Page 6: ...ay from incoming water 5 Be sure the float switch is at least 1 in away from the side walls of the basin and free of any obstructions through the full range of switch motion 6 Install rigid 2 in discharge pipe not included according to local regional and state codes Incoming water Switch Switch 1 in Minimum Discharge Pipe ...

Page 7: ...e pump discharge to prevent air lock Pumps have a vent located in the pump but an additional vent hole is recommeded Water stream will be visible from this hole when the pump is running The hole must be cleaned periodically 9 Install a 2 in union not included above the basin to allow the pump to be removed for cleaning and service Discharge Pipe Additional 3 16 in Vent Hole Union 7 8 9 ...

Page 8: ...ot included above the union to prevent back flow 11 Install a 2 in gate valve not included above the check valve as required by local regional or state codes 12 Connect remaining discharge pipe into main waste line to sewer or septic tank Check Valve Gate Valve Main waste line 10 11 12 ...

Page 9: ...ow the float switch to move freely 14 Connect pump power supply cord to a receptacle protected by a ground fault circuit interruptor GFCI Cable or Zip Ties GFCI protected receptacle 13 14 15 Fill the basin with water to check operation The pump will start when the water level has reached the switch on level Refer to page 4 for on level On 15 ...

Page 10: ...o the basin and prevent personal injury Basin cover and gasket 16 17 Install a vent pipe not included according to local regional or state codes to remove gases and odors Vent pipe 17 MOTOR DATA CHART HP Phase Volts Max Amps Locked Rotor Amps 1 2 1 115 9 8 19 5 PERFORMANCE Item Number HP Ft of Head Flow GPM Shut Off Head Ft Discharge Size 1263 1 2 0 103 18 2 in 5 90 10 60 15 23 SPECIFICATIONS ...

Page 11: ...ve if necessary Pump shuts off and turns on independently of switch trips thermal overload protection 1 Excessive water temperature 1 Pump should not be used for water above 104 F 40 C 2 Switch is defective 2 Replace switch 3 Switch is obstructed 3 Remove obstruction to ensure free motion of switch 4 Discharge pipe is clogged 4 Remove clog in discharge piping 5 Low line voltage 5 Contact an electr...

Page 12: ...closed or installed backwards 4 Be sure check valve is installed and operating properly Replace check valve if necessary 5 Shut off valve closed 5 Open shut off valve TROUBLESHOOTING CARE AND MAINTENANCE WARNING Always disconnect pump from power supply before handling Inspect and test system for proper operation at least every three months 1 Remove any build up of debris from the switch or float a...

Page 13: ...her than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE ANY IMPLIED W...

Page 14: ...x6 0 2 Capacitor Kit 025383 Includes capacitor cap screws M6 1 0x15 mounting screw M4 0 7x6 case o ring 115x4 NBR 3 Base Kit 025388 Includes pump base screws M5 0 8x15 4 Cap Kit 025385 Includes cap screws M6 1 0x15 GND screw M4 0 7x6 0 case o ring 115x4 NBR cap with handle guard and plug nameplate screw M3x1 34 switch to case screws switch 5 Float Kit 025381 Includes guide rod guide strap float RE...

Page 15: ...15 2020 All rights reserved WIRING DIAGRAM 3 L1 L2 1 2 1 2 3 4 RUN O L MOTOR BLUE RED SWITCH BLACK WHITE GREEN START YELLOW BLUE RED CAPACITOR COM NC FLOAT BLACK OR WHITE BLACK OR WHITE ...

Page 16: ...16 2020 All rights reserved ...