1. Sewage pumps are pumps used to remove
waste water that contains solids up to 2 in.
in diameter. The most common application is
for draining bathroom waste water to a sewer
or septic line.
Three prong
grounded
outlet
equipped
with a
ground fault
interruptor
2 in. Discharge
pipe
Upper level drainage
Cleanout
Flange
Lavatory
45°
Elbow
2 in. Check
valve
2 in. gate valve
Union
Vent pipe
Sink
Main waste
line to sewer
or septic tank
Switch
Pump
Vent hole
1
2. These pumps are equipped with a float switch. The
pump will turn on automatically when the water level in
the basin reaches the “on” level.
On
2
Off
3
Item
On Level
Off Level
1263
10.25 in.
5 in.
3. The pump will turn off automatically when the water
level in the basin reaches the “off” level.
GENERAL PUMP INFORMATION
5
© 2020. All rights reserved.
INSTALLATION INSTRUCTIONS
30 in.
18 in.
1. Use a basin (not included) that is at least 18 in. wide
by 30 in. deep.
1
2. Clean the basin of all debris.
2
3. Set the pump on a solid, level surface. A brick or block
(not included) may be installed under the pump to
provide a solid base.
3
Summary of Contents for 1263-0001Q