4
4.2 Electric connections
• the electrical supply of the heater must come from a protection and switching device (not supplied)
complying with the standards and regulations in force in the country where it is installed (in France,
refer to standard NF C 15100). The RE/U from 3 to 9 kW may be supplied by single-phase
(230V/1N/50Hz) see figure 1, or in three-phase (400V/3N/50Hz), see figure 2. The 21 and 24 kW
RE/U
must
be supplied with three-phase current (400V/3N/50Hz).
• supply cable section: this section is recommended for cables of a maximum length of 20 metres,
with a calculation base of 5A/mm². It must be checked and adapted if necessary, depending on
installation conditions:
Power
Current consumption
Cable section
Single-phase
230V-1N-50Hz-
Three-phase
400V-3N-50Hz-
Single-phase
230V-1N-50Hz-
Three-phase
400V-3N-50Hz-
9 kW
40 A
13 A
3 x 10 mm²
3G10
5 x 4 mm²
5G4
12 kW
53 A
18 A
3 x 16 mm²
3G16
5 x 4 mm²
5G4
15 kW
66 A
22 A
3 x 16 mm²
3G16
5 x 6 mm²
5G6
18 kW
79 A
26 A
3 x 16 mm²
3G16
5 x 6 mm²
5G6
21 kW
31 A
5 x 10 mm²
5G10
24 kW
35 A
5 x 10 mm²
5G10
• electrical protection: 30 mA differential circuit breaker (at the head of the line).
WARNING! The appliance shall be connected to ground.
Figure 2
Figure 1
A = 540 (±1mm) in the case of the
PVC filtration system Ø50
B = 600 (±1mm) in the case of the
PVC filtration system Ø63
From
pool
To pool
Pump
Filter
Water treatment
Minimum flow rate: 5 m³/h
Maximum flow rate: 22 m³/h
Single-phase main supply 230V-1N-50Hz + Earth
start point terminal
start point terminal
Cable 1,5mm²
Phase
Clamp
Câble
1,5mm²
Cable 1,5mm²
shunted
terminals*
Neutral
Neutral
Three-phase main supply 400V-3N-50Hz+Earth
Earth
Phase
Earth
Phase 1
Phase 2
Phase 3
shunted
terminals*
* waiting for the connection of a remote control