Heat pump dimensions 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical characteristics

 

 

 

          * With an ambient air temperature of + 15°C and a pool water temperature of 24°C  

  

 

 

• Unit protection class: 

IP 24

 

 

• Type of refrigerant: 

R410A 

 

(see product name plate for refrigerant charge)

 

 

 

Do not vent R410A into atmosphere: R410A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a 

Global Warming Potential (GWP) = 1975 - (Directive of the EC 842/2006) 

 

 

• Ambient operating temperature (TS): Min. 

5°C

 / Max. 

38°C

 

Heat pump 

Input* 

Output* 

Nominal 

current 

consumption* 

Max. current  

consumption 

Sound 
power 

Sound 

pressure at 

10 m 

Net weight 

PowerPAC 1M 

1.42

  kW 

6.6

   kW 

6.28

   A 

9

 A 

   

66.4

 dBA 

  

38.4

 dBA 

45

  kg 

PowerPAC 2M 

1.64

 kW 

7.8

   kW 

7.34

   A 

10

 A 

   

67.4

 dBA 

   

39.4

 dBA 

46

  kg 

PowerPAC 3M 

2.2

  kW 

11

   kW 

10.5

   A 

14.5

 A 

   

68

 dBA 

40

 dBA 

60

  kg 

Controller 

 

 

 : 

On/Off or Stand-by 

(press and hold 3 s)

.

 

:

 

Display required water temperature

+

 

 

: Increase required water temperature. 

+

: Decrease required water temperature.

Controller ON indicator 

Priority Heating output enabled indicator  

Compressor ON (steady) or timed (blinking) indicator 

Defrost in progress (steady) or timed (blinking) indicator

     

 

Indicators not active 

n

 

o

 

p

q

 

r

t

 

s

 

u

 

v

 

nn

 

no

 

nm

 

 

np

 

n

 Front panel. 

o

 Fan grid.  

p

 Controller. 

q

 Side panel (access to technical zone). 

r

 ‘Flat fin’ evaporator. 

s

 Pool water inlet. 

t

 Pool water outlet 

u

 Cable gland. 

v

 Top panel. 

nm

 Structural post. 

nn

 Base. 

no

 Grooved end piece of evacuation of condensation. 

np

 Product name plate.

 

Summary of Contents for POWER PAC 1M

Page 1: ...Heat pump Instructions for installation and use F GB D NL E P I Ed 09 2008 R f 1011505 01 374274003 00 1M 2M 3M POWER PAC...

Page 2: ...efore beginning any installation handling or repair work on the heat pump always isolate the electrical power supply to the unit In the case of a fault and or operating error on the heat pump the elec...

Page 3: ...uired for installation 4 Selection of installation site 4 CONNECTIONS 5 Access to technical compartment 5 Hydraulics 5 Electrical 5 COMMISSIONING 7 Preliminary inspections 7 Commissioning step by step...

Page 4: ...y available refer to the chapter DESCRIPTION for location of the name plate Water treatment For our appliances to function under the best possible conditions the following parameters must be respected...

Page 5: ...6 kW 6 28 A 9 A 66 4 dBA 38 4 dBA 45 kg PowerPAC 2M 1 64 kW 7 8 kW 7 34 A 10 A 67 4 dBA 39 4 dBA 46 kg PowerPAC 3M 2 2 kW 11 kW 10 5 A 14 5 A 68 dBA 40 dBA 60 kg Controller On Off or Stand by press a...

Page 6: ...t pump must be installed at a minimum distance from the pool This distance is defined by the locally valid electrical regulations In France the standard NF C 15 100 section 702 specifies that the unit...

Page 7: ...ter flow rate 2 8 3 5 5 m3 h head loss 0 12 to 0 15 bar Electrical The electrical power supply to the heat pump must be protected with a fuse and isolator switch not provided in compliance with standa...

Page 8: ...nd monitoring of the pool heating requirements even when the filter system has been switched off by the timer Connection of the Priority Heating function Use terminals 16 and 17 to control filter pump...

Page 9: ...Note in the aforementioned configuration the heat pump is not yet supplied with pool water 2 Switch on the filter system 3 Progressively close valve V1 in order to increase the filter pressure to 150...

Page 10: ...en 5 and 5 C the fan is switched off The compressor and fan restart after a time period of 2 to 5 minutes varies according to the compressor stoppage time If the ambient temperature drops below 5 C th...

Page 11: ...matic if less than 4 dbP or dHP faults in one hour or press the key if the message dSr is blinking Alternating with the pool water temperature Water flow rate sensor fault ST4 Sensor defective or disc...

Page 12: ...a high pressure spray Ensure no foreign bodies obstruct the fan grid Annual by a qualified and authorised technician Carry out the regular maintenance tasks refer to paragraph above Check the target...

Page 13: ...G DIAGRAM With an aim to continuous improvement the products may be modified without prior notice Edition of 09 08 A IMPORTANT Elimination or shunting of a safety or remote control device automaticall...

Page 14: ...e eliminated or neutralised Your appliance is reaching the end of its working life You would like to get rid of it or replace it Please do not throw it into the dustbin or into your local council s se...

Page 15: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 16: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 17: ...t be carried out with total respect of valid safety regulations and acceptable professional practice recuperation of refrigerant nitrogen brazing etc All brazing work must be carried out by a qualifie...

Page 18: ...yst mes de chauffage et de d shumidification de piscines En s appuyant sur le savoir faire technologique et l exp rience de PSA Zodiac vous apporte la garantie d appareils de tr s haut niveau tant dan...

Page 19: ...hank you for trusting us and enjoy your bath at 28 C Please take a little time to fill in this guarantee form with your pool adviser Your details may be treated according to the law Informatique et ci...

Page 20: ...n de s rie Type and serial number Utilisateur Owner Installateur installer Station service agr e PSA Technical support Garantie guaranty Date de livraison Delivery date Date de mise en route Date of...

Reviews: