3

2. Installation

2.1  Recommendations 

 Warning: pH Perfect must be installed by an experienced pool professional.

  Before carrying out any installation or maintenance of the pH Perfect control centre, disconnect it 

from the mains power supplies.

  Before starting to install the pH Perfect, check that you have all the components listed above  and 

ensure you read this instruction manual carefully.

  This appliance is not intended for use by persons (including children) that lack experience and 

knowledge, unless they have been given supervision or instruction concerning use of the appliance 
by a responsible person.

  Children should be supervised to ensure that they do not play with the device.

  The installation of this device should be carried out by a qualified person in accordance with the 

Australian wiring rules AS/NZS 3000.

  The control centre should be located in the correct pool zone and connected to supply via a power 

outlet that is protected by a residual current device (RCD) having a rated residual operating current 
not exceeding 30mA.

  The power outlet should have a degree of protection suitable for the pool zone

  Ensure that equipotential bonding of all parts of the pool installation is carried out.

  During the installation phase of the pH Perfect, check the following:

•  that the voltage of the power supply corresponds to the voltage indicated on the side of the 

appliance

•  that the injection point pressure is lower than 1.5 Bar
•  that the peristaltic pump's protection cover is correctly fitted
•  that the suction tube is immersed in the corrective solution (pH up or down) container with the 

suction tube also connected to the peristaltic pump (left side).

•  that the injection tube is connected on one side to the peristaltic pump (right side) and on the 

other side to the pool return pipe via the injection valve.

  Zodiac Group Australia Pty Ltd will not be held liable for the use of this device with inappropriate 

products.

  The pH sensor is fragile, it must be handled with care. Try to avoid touching the tip with your fingers.

2.2  Technical details

Dimension (L - W - H) 

240 x 200 x 90mm

Weight (appliance, sensor, tube and pipes) 

1.7 kg

Power feed 50Hz 

220-240 V AC/50 Hz

Consumption 12W
Pump flow rate 

1.5 l/hr

Maximum back pressure 

1.5 bar

pH control range 

0.0 pH-14.0 pH

Appliance accuracy 

+/- 0.1 pH

Calibration of the sensor 

7.5 pH

If the supply cord is damaged, it shall be replaced by the manufacturer or its 
service agent, or similarly qualified person in order to avoid a hazard.

Summary of Contents for pH Perfect

Page 1: ...Owners Manual and Warranty Information Please read thoroughly before starting device...

Page 2: ...he Control Panel 2 2 Installation 2 1 Recommendations 3 2 2 Technical details 3 2 3 Installation Diagram 4 2 4 Installation of the Sensor POD 5 3 Starting up and operating 3 1 Calibration procedure 7...

Page 3: ...id risk of injury to persons or damage to the appliance The symbol indicates useful information 1 1 Identification of parts 1 Control box 2 Mounting bracket and screws 3 Hole saw 4 Tubing 5 POD assemb...

Page 4: ...is connected to the regulator unit with this connector Master switch for powering the control unit Navigation button q for navigating in the menu SET Esc button button for exiting from the menu also f...

Page 5: ...tential bonding of all parts of the pool installation is carried out During the installation phase of the pH Perfect check the following that the voltage of the power supply corresponds to the voltage...

Page 6: ...nd the life of the peristaltic tube the pressure should not exceed 1 bar Install the pH Perfect control centre using the supplied fixing kit on a rigid support a vertical wall in an easy to access loc...

Page 7: ...ided hole saw Ensure that holes are perfectly smooth around the edges picture 3 7 Position the upper part of POD clamp by sliding it into the 2 previously drilled holes NOTE arrows on upper part of PO...

Page 8: ...mic weight on the suction tube and then fit the small blue barb fitting to the end of the tube to prevent the weight from falling off see picture B 6 Now connect the injection tubing to the injection...

Page 9: ...Then shake gently to remove excess water 4 Pour a small amount of pH 7 5 calibration fluid into a small bottle enough to cover the end of the sensor tip Then immerse the sensor into the fluid Discard...

Page 10: ...onditions the quickest but with the least possible corrective solution your pH Perfect automatically detects the difference of the pH value measured in the pool compared with the desired set point def...

Page 11: ...100 ppm the pH will be potentially unstable and it will be the opposite if the total water hardness is high 150 ppm In order to always have an optimal balance the pH Perfect has a function making it...

Page 12: ...p and q navigation buttons to save the new settings or not Accept the choice by pressing the CAL Enter button B 4 2 Language You can choose between 6 languages for the LCD display French English Germa...

Page 13: ...date by pressing the CAL Enter key Indication of the choice of alkalinity level TAC 100 ppm Low 100 TAC 150 ppm Std Standard default setting TAC 150 ppm High 4 6 OFA over feed protection Your pH Perfe...

Page 14: ...48 hours Presser Press p q CAL OFA disabled for 24 hours automatically re enabled Presser Press p q SET OFA disabled for 48 hours automatically re enabled 4 7 Detection that filtration is in progress...

Page 15: ...tablet holder clockwise and at the same time put the tube into the pump head up to the right hand connection 5 Replace the protective cover place the pin in the attachment hole 2 Position the tablet h...

Page 16: ...te Add calcium chloride Add cyanuric acid only if necessary To reduce Use pH perfect in acid dosage and or decrease setpoint Stop adding chlorine Add diluted hydrochloric acid Add a scale fixer or car...

Page 17: ...ensor cable is too close to a power cable causing interference Reduce the distance between the appliance and the sensor and or place the cable elsewhere Impossible to calibrate error message Quality o...

Page 18: ...ike 4 Without limiting 3 above products sold by Zodiac Australia are designed for use with swimming pool water balanced in accordance with Australian Standard AS3633 1989 with a pH range of 7 0 7 8 Ma...

Page 19: ...foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Purchasers in...