background image

17

9. Warranty

9.  Zodiac Australia reserves the right to determine, in relation to each warranty claim, whether the 

Product should be returned to the Authorised Dealer at the address where the Purchaser purchased 
the Product or whether warranty service will be provided in the field, repaired at a Zodiac workshop 
or at the premises of an authorized Zodiac warranty agent.

10.  If it is necessary for the Purchaser to incur freight charges in making a valid claim under this 

warranty, Zodiac Australia will reimburse the Purchaser for charges reasonably incurred upon proof 
of the charges.

Additional guarantees, rights and remedies

Australian Purchasers – Guarantees under the Australian Consumer Law

11.  The benefits of this express warranty are in addition to other guarantees, rights and remedies 

Australian consumers have under the Australian Consumer Law.

12.  Zodiac Australia products come with guarantees that cannot be excluded under the Australian 

Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation 
for any other reasonably foreseeable loss or damage. You are also entitled to have the goods 
repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a 
major failure.

Purchasers in other Countries

13.  The laws and regulations of other countries may confer on Purchasers in those countries additional 

rights and remedies. To the extent that they cannot be excluded or modified, Purchasers have the 
benefits of those rights and remedies in addition to the benefits of this express warranty. To the full 
extent that it is permissible to do so, those additional rights and remedies are excluded or modified 
so as to be consistent with Zodiac Australia's express warranty.

INCONSISTENCY WITH WARRANTY STATEMENTS IN PRODUCT MANUALS 
OR OTHER DOCUMENTS ACCOMPANYING PRODUCTS

If any warranty statements in a Zodiac Australia product manual or other document are inconsistent 
with the above Express Warranty and Guarantees, the above overrides and replaces the inconsistent 
statements.

10.  Online registration

Registration on line

Register your product on our website:
•  you will be the first to be informed of new Zodiac products and special offers,
•  You can help us to constantly improve the quality of our products.
Australia – New Zealand 

www.zodiac.com.au

Summary of Contents for pH Perfect

Page 1: ...Owners Manual and Warranty Information Please read thoroughly before starting device...

Page 2: ...he Control Panel 2 2 Installation 2 1 Recommendations 3 2 2 Technical details 3 2 3 Installation Diagram 4 2 4 Installation of the Sensor POD 5 3 Starting up and operating 3 1 Calibration procedure 7...

Page 3: ...id risk of injury to persons or damage to the appliance The symbol indicates useful information 1 1 Identification of parts 1 Control box 2 Mounting bracket and screws 3 Hole saw 4 Tubing 5 POD assemb...

Page 4: ...is connected to the regulator unit with this connector Master switch for powering the control unit Navigation button q for navigating in the menu SET Esc button button for exiting from the menu also f...

Page 5: ...tential bonding of all parts of the pool installation is carried out During the installation phase of the pH Perfect check the following that the voltage of the power supply corresponds to the voltage...

Page 6: ...nd the life of the peristaltic tube the pressure should not exceed 1 bar Install the pH Perfect control centre using the supplied fixing kit on a rigid support a vertical wall in an easy to access loc...

Page 7: ...ided hole saw Ensure that holes are perfectly smooth around the edges picture 3 7 Position the upper part of POD clamp by sliding it into the 2 previously drilled holes NOTE arrows on upper part of PO...

Page 8: ...mic weight on the suction tube and then fit the small blue barb fitting to the end of the tube to prevent the weight from falling off see picture B 6 Now connect the injection tubing to the injection...

Page 9: ...Then shake gently to remove excess water 4 Pour a small amount of pH 7 5 calibration fluid into a small bottle enough to cover the end of the sensor tip Then immerse the sensor into the fluid Discard...

Page 10: ...onditions the quickest but with the least possible corrective solution your pH Perfect automatically detects the difference of the pH value measured in the pool compared with the desired set point def...

Page 11: ...100 ppm the pH will be potentially unstable and it will be the opposite if the total water hardness is high 150 ppm In order to always have an optimal balance the pH Perfect has a function making it...

Page 12: ...p and q navigation buttons to save the new settings or not Accept the choice by pressing the CAL Enter button B 4 2 Language You can choose between 6 languages for the LCD display French English Germa...

Page 13: ...date by pressing the CAL Enter key Indication of the choice of alkalinity level TAC 100 ppm Low 100 TAC 150 ppm Std Standard default setting TAC 150 ppm High 4 6 OFA over feed protection Your pH Perfe...

Page 14: ...48 hours Presser Press p q CAL OFA disabled for 24 hours automatically re enabled Presser Press p q SET OFA disabled for 48 hours automatically re enabled 4 7 Detection that filtration is in progress...

Page 15: ...tablet holder clockwise and at the same time put the tube into the pump head up to the right hand connection 5 Replace the protective cover place the pin in the attachment hole 2 Position the tablet h...

Page 16: ...te Add calcium chloride Add cyanuric acid only if necessary To reduce Use pH perfect in acid dosage and or decrease setpoint Stop adding chlorine Add diluted hydrochloric acid Add a scale fixer or car...

Page 17: ...ensor cable is too close to a power cable causing interference Reduce the distance between the appliance and the sensor and or place the cable elsewhere Impossible to calibrate error message Quality o...

Page 18: ...ike 4 Without limiting 3 above products sold by Zodiac Australia are designed for use with swimming pool water balanced in accordance with Australian Standard AS3633 1989 with a pH range of 7 0 7 8 Ma...

Page 19: ...foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Purchasers in...

Page 20: ...stralia 219 Woodpark Rd Smithfield NSW 2164 Australia Tel 1300 763 021 Fax 1300 781 688 Email apac aftersales zodiac com www zodiac com au Due to constant developments and improvements specifications...

Reviews: