Page 6
ENGLISH
Zodiac
®
Jandy
®
Heat Pumps Model EE-Ti
|
Installation and Operation Manual
table 1.
ee
-t
i Heat
pump
technical
specifications
M
odel
ee
1500
t
ee
2000
t
ee
20
00
t-
-2
63
ee
2500
t
ee
2500
t-
r
ee
25
00
t-
-2
63
ee
25
00
t-
r
26
3
ee
3000
t
ee
3000
t-
r
ee
30
00
t-
-2
63
ee
30
00
t-
r
26
3
VOLTAGE
23
0/
60
/1
23
0/
60
/1
23
0/
60
/3
23
0/
60
/1
23
0/
60
/3
23
0/
60
/1
23
0/
60
/3
OUTPUT*
70
,0
00
B
TU
s
112,000 BTUs
120,000 BTUs
140,000 BTUs
INPUT*
3.
3
kW
5.1 kW
5.6 kW
6.7 kW
COP*
6.4
6.4
6.3
6.1
OUTPUT, STANDARD RATING CONDITIONS**
60,000 BTUs
93,000 BTUs
105,000 BTUs
130,000 BTUs
COP, STANDARD RATING CONDITIONS**
5.4
5.4
5.5
5.5
OUTPUT, LOW AMBIENT**
40,000 BTUs
64,000 BTUs
72,000 BTUs
85,000 BTUs
COP, LOW AMBIENT**
4.0
4.0
4.0
4.0
RLA (RUNNING LOAD AMPS)
21A
26.9A
19.2A
26.9A
23A
26.9A
26.9
LRA (LOCKED ROTOR AMPS)
115A
145A
170A
145A
160A
145A
190A
MINIMUM CIRCUIT AMPACITY
28A
37A
27A
37A
32A
37A
36A
MAX OVER CURRENT PROTECTION***
45A
60A
45A
60A
50A
60A
HEAT EXCHANGER
Titanium
COMPRESSOR
40K Scroll
61K Scroll
68K Scroll
83K Scroll
CABINET
ABS
REFRIGERANT
64 Oz, R410A
74 Oz, R410A
90 Oz, R410A
90 Oz, R410A
90 Oz, R410A
90 Oz, R410A
114 Oz, R410A
124 Oz, R410A
114 Oz, R410A
124 Oz, R410A
R
EF
R
IG
ER
AN
T
H
IG
H
P
R
ES
SU
R
E
AL
AR
M
650 PSI (reset to 460 PSI)
R
EF
R
IG
ER
AN
T
LO
W
P
R
ES
SU
R
E
AL
AR
M
-
H
EA
TI
N
G
U
N
IT
S
58 PSI (reset to 127 PSI)
R
EF
R
IG
ER
AN
T
LO
W
P
R
ES
SU
R
E
AL
AR
M
-
R
EV
ER
SE
U
N
IT
S
35 PSI (reset to 74 PSI)
LOW WATER FLOW ALARM
30 GPM
MAXIMUM HEIGHT BELOW WATER LEVEL
10 feet below pool level
MINIMUM HEIGHT ABOVE WATER LEVEL
5 feet above pool level
OPTIMAL WATER FLOW
60 GPM
MINIMUM WATER FLOW
30 GPM
MAXIMUM WATER FLOW
125 GPM
AIR FLOW
2060 CFM
4120 CFM
WATER TEMPERATURE DIFFERENTIAL (DELTA T)
Adjustable between 1
°F to 5
°F
UNION SIZE
2”
WEIGHT
225 LBS
325 LBS
SOUND PRESSURE PER ISO 3471
58.9 dBa
OUTPUT - Chiller****
NA
71,000 BTUs
54,000 BTUs
INPUT - Chiller****
NA
6.9 kW
7.2 kW
COP - Chiller****
NA
3.01
2.22
OUTPUT - Chiller*****
NA
87,000 BTUs
60,000 BTUs
INPUT - Chiller*****
NA
7.4 kW
7.3 kW
COP - Chiller*****
NA
3.46
2.4
* T
est Conditions: 80
˚
F Air
, 80% RH, 80
˚
F W
at
er
, Outside the scope of AHRI Standar
d 1
160 (I-P)
** Rat
ed in accor
dance with AHRI Standar
d 1
160 (I-P)
*** Max Ov
er Current Pr
ot
ection ref
er
s t
o the maximum break
er size allo
w
ed. If this v
alue is no
t a standar
d break
er size, use the ne
xt smallest standar
d size break
er
.
The break
er size must no
t be smaller than the Minimum Cir
cuit Am
pacity v
alue.
**** T
est Conditions: Chiller mode, 96° F Air
, 50% RH, 80° F W
at
er
, Ouside the scope of AHRI Standar
d 1
160 (I-P)
***** T
est Conditions: Chiller mode, 96° F Air
, 50% RH, 95° F W
at
er
, Ouside the scope of AHRI Standar
d 1
160 (I-P)
Summary of Contents for Jandy EE-Ti