Page 17
ENGLISH
Zodiac
®
Jandy
®
Heat Pumps Model EE-Ti
|
Installation and Operation Manual
Relay is needed. See Figure 10.
4.5
optional remote Controls
Electrical wiring must be in accordance with all
applicable national and local codes and ordinances.
4.5.1 Connection to a remote pool-off-
spa selector (3-Wire Connection)
4.5.1.1 install the remote pool-off-spa
selector
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (see Figure 11).
3. Run the wires from the pool/spa control system
into the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand side
of the heat pump (see Figure 11).
4. Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(see Figure 12a).
5. Restore power to the heat pump and the pool/spa
control system.
4.5.1.2 Configure the Control panel
1. Make sure the control is in the
oFF
mode.
2. To enter the Service Setup mode, press and hold
the
Menu
,
pool
, and
spa
buttons for 5
seconds.
note
The display will revert back to
oFF
after one
minute since the last key press.
3. Press the
up
or
down
button to display
reMote
. Press the
Menu
button. The
seleCt reMote oFF
(default remote)
appears, use the
up
or
down
button to scroll
through the Remote options. When you reach
Hi-
lo-CoM
, press the
Menu
button to select the
remote. Press
pool
or
spa
to exit the Service
Setup mode.
4.5.2 two-Wire Connection to an
aqualink
®
rs or tstat
4.5.2.1 Configure the aqualink rs Control
system
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Connect two (2) wires to the AquaLink RS green
10-pin terminals 1 and 2.
3. Put DIP S2-1 (pin #1 of the 4 position DIP switch)
into the ON position (see Figure 13).
4.5.2.2 install the remote tstat
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (See Figure 11).
3. Run the wires from the pool/spa control system
into the conduit connection labeled “low voltage
connection”, located on the lower right hand side
of the heat pump (See Figure 11).
Figure 13. aqualink rs to ee-ti Heat pump
Heat Pump
Green - Enabled
Red - On
Heat Pump Connections
Terminals 1 and 2
Connector for Low
Voltage Wires
DIP Switches
S1 and S2
S1
S2
RESET
SERVICE
TIME OUT
FIL
TER PUM
P
AUX
1
AUX
2
AUX
3
AUX
4
AUX
5
AUX
6
AUX
7
RS6 & RS8 ONLY
RS8 ONLY
HEATER
SOLAR
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
AUTO
6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1 4 3 2 1
S1
S2
OFF ON
OFF ON
1 2 3 4 5 6 7 8
1 2 3 4
Thu January, 2009 3:03 PM
AquaLink Touch
Home
Menu OneTouch
Help
Back
Status
Photos Power
FILTER
PUMP
SPA
POOL
HEAT
Pool Temp
86º
Air Temp
78º
SPA
HEAT
AUX1
AUX2
AUX3
Other
Devices
On/Off
Green - Enabled
Red - On
Summary of Contents for Jandy EE-Ti