![Zodiac eXPERT Instructions For Installation And Use Manual Download Page 18](http://html1.mh-extra.com/html/zodiac/expert/expert_instructions-for-installation-and-use-manual_4037713018.webp)
17
2.6.2. Detail of connections
Contact closed (ON)
Contact open (OFF)
Activate the function
Pool Cover
Pool cover closed: reduced
production (10% to 90%)
Pool cover open : 100%
production
See§ “4.3.7. “Cover”:
Connecting a pool cover”
Slave mode
External chlorination controller
connected (ORP or PPM)
No external chlorination
controller (ORP or PPM) or
automatic ORP regulation (pH/
ORP model)
See § “4.3.12. “Cl EXT”: Slave
mode”
Flow switch*
Flow switch detected
No flow detected:
Alarm
See § “4.3.5. “Flow”:
Activating the flow switch”
pH pump
230 V supply when pH correction is needed (depending on
model)
See § “2.6.3. pH pump
connection (for pH - PH/ORP
models)”
(*Flow switch comes already wired from the factory)