ENGLISH
Installation and general maintenance manual
- VARIABLE SPEED PUMP
24
2. OVERVIEW OF THE SYSTEM
Before starting, check that you have all of the parts shown in Figure 1.
TABLE 1 -
CONTENTS
E30iQ Pump
Union Nut, tailpiece, O-ring, cable gland (qty 2 each)
TABLE 2 -
SPECIFICATIONS
Unit
E30 iQ 100
E30 iQ 200
Operating Water Temperature
2 to 35°C
Nominal Voltage of Motor
230 VAC-50 Hz
Motor Power - Phase
1P
Admissible Variation in Motor Voltage
± 10% (during operation)
Maximum Power at Motor Input (P1)
W
1097 (at105%)
1790 (at105%)
Maximum Motor Amperage
A
7.8
12
Cable Cross-Section
mm
2
3x1.5
Lug Type
3G1.5
Electrical Protection
A
10
16
Fuse
10A 5x20mm
16A 5x20mm
Motor Protection Rating
IPX5
Maximum Pump Flow
m
3
/h
23
34
Pump Flow Rate at 10m of Head
m
3
/h
15,4 (at100%)
25 (at 100%)
Pump Flow Rate at 8m of Head
m
3
/h
17,3 (at 100%)
27,3 (at 100%)
H Max
mH20
18
20,4
Maximum Pump Pressure
bar
1,8
2,04
Pump Pipe Connection
2” threaded suction/discharge
Ø63/50 mm union couplings
Maximum Pump Salinity
6g/L (6000 ppm)