AERAZUR
COMPONENT MAINTENANCE MANUAL
C10 LIFE JACKET
25-65-09
REV
12
PAGE
701
ASSEMBLY (INCLUDING STORAGE)
1.
General
After checking the life jacket, carry out reassembly in the reverse order of disassembly.
Work on a clean work table covered with a protective material, free of any object likely to
damage the life jacket.
For the equipment and products required, refer to the “SPECIAL TOOLS, FIXTURES
AND EQUIPMENT MATERIALS” section.
2.
Preparation
A.
If necessary, install the life jacket’s various components and accessories as shown on
figure 701.
Refer to the "REPAIR" section for fitting and replacing components and accessories.
Check:
The fitting and tightness of the CO
2
cylinder with its manifold gasket
(tightening torque: refer to the "FITS AND CLEARANCES " section);
The fitting of the mouthpiece;
The presence and adherence of the adhesive strips on the buoyancy chamber;
Appl.A:
The presence of new gaskets;
The tightness of the nut cap
(tightening torque : refer to the "FITS AND CLEARANCES" section);
The installation of the inflator sheath;
The locking of the inflator lever with break thread;
The dehydration capsule is installed;
The rescue light system is present.
Remove the pull tab plug before fitting
.
Appl.B, C et D:
The presence of the rescue light system.
The inflator lever is locked with the safety clip; Remove pull-tab if necessary.
The document reference is online, please check the correspondence between the online documentation and the printed version.