AERAZUR
COMPONENT MAINTENANCE MANUAL
C10 LIFE JACKET
25-65-09
REV
12
PAGE
301
DISASSEMBLY
1.
General
For the testing equipment required, refer to the “SPECIAL TOOLS, fixtures and
EQUIPMENT MATERIALS” section.
The work table must be clean and adequately lit. It must be covered with a protective
material and free from all objects likely to perforate or tear the life jacket.
2.
Procedure
Remove the life jacket from its carrying bag/pouch;
Lay it flat on the work table.
A.
Appl.A (refer to Figure 301)
Unscrew and remove the nut-cap (1) by using a 9/16” tubular spanner;
Remove the top gasket (2);
Remove the manual inflator (3)/CO
2
cylinder (4) assembly;
Remove the inflator sheath (5);
Remove the bottom gasket (6);
Unscrew and remove the CO
2
cylinder (4);
Remove the manifold gasket (7);
Remove the valve core (8) by using the valve core tool;
Remove the rescue light system (9) ;
CAUTION :
BATTERY AND LAMP CANNOT BE SEPARATED.
C10 F only
: remove the whistle (10) by cutting the cord and taking off the rubber
band;
Unstick the double sided adhesive tape (11);
Remove the mouthpiece (12) by using the check valve remover.
B.
Appl.B, C and D (refer to Figure 302)
Unscrew and remove the CO
2
cylinder (1);
Remove the manifold gasket (2);
Remove the rescue light system (3);
CAUTION :
BATTERY AND LAMP CANNOT BE SEPARATED.
C10 F only
: remove the whistle (4) by cutting the cord and taking off the rubber
band;
Unstick the double sided adhesive tape (5);
Remove the mouthpiece (6) by using the check valve remover.
The document reference is online, please check the correspondence between the online documentation and the printed version.