The modules have passed mechanical load test 5400Pa,To avoid exceeding the maximum load, site-

specific live loads such as wind and snow should be taken into account.   

● 

The installation of project must be facing north in the southern hemisphere, and facing south in the 

northern hemisphere, the electricity will be comparatively lower when the project facing west or east. 

The incorrect installation will lead to the loss of power   

 

 

 

 

 

 

 

 

 

● 

The modules, which are connected in series, must be in the same angle, otherwise, it will lose power 

because of the difference in sunlight intensity. Solar modules generate the power to the maximum when 

they are pointed directly at the sun. For installations where the solar modules are mounted to a 

permanent structure, the solar modules should be tilted for optimum winter performance. As a rule, if 

the system power output is adequate in the winter, it will be satisfactory during the rest of the year. The 

module tilt angle is measured between the solar modules and the ground. 

 

                                                     

 

Avoid installing under the shadow, even the module factory use the bypass diode to decrease the loss of 

energy, the shadow will lead to the loss of output power. 

 

4、

Grounding   

All  module  frames  must  be  attached  to  an  earth  ground.  A  qualified  electrician  must  do  the  ground 

connection .The cable which connects the earth must be copper wire with 12AWG.   

RECOMMENDED TILT ANGLES FOR A FIXED SYSTEM   

SITE LATITUDE IN DEGREES   

FIXED TILT ANGLE   

0

 o

 TO 15

 o

 

  15

 o

 

15

o

 TO 25

o

 

  SAME AS LATITUDE   

25

o

 TO 30

o

 

  L5

 o

 

30

o

 TO35

o

 

  L10

 o

 

35

o

 TO 40

o

 

  L15

 o

 

40

o

    +   

L20

 o

 

Summary of Contents for ZXM6-H144

Page 1: ...ration and maintenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and mainte...

Page 2: ...H120 ZXP6 H120 Max series fuse rating A 15 Nominal Mass 22 5kg 21 5kg 21kg 20 5kg 20 5kg 19 5kg Package Size mm 2000x992x40 35 2024x1002x40 35 2020x1002x40 35 2040x1002x40 35 1844x992x40 35 1860x1002...

Page 3: ...ces If there is exposure to salt i e marine environment and sulfur i e sulfur sources volcanoes there is a risk of corrosion It s not recommended to install the modules when the distance is less than...

Page 4: ...ns where the solar modules are mounted to a permanent structure the solar modules should be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will...

Page 5: ...he bolt and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or...

Page 6: ...secure the modules to support structure Always use all the eight mounting holes to secure the modules The module installed with screws on the front frame for load see the following picture and refer...

Page 7: ...can run off freely to avoid standing water or pudding This resistance value can decrease if modules are not mounted following the instructions above B Clamping installation Only for frame with 40mm t...

Page 8: ...just for reference Customer can select the corresponding installation manual based on the purchased module 7 Wiring The modules use thePV JX1203 type junction box This box on the back side of the modu...

Page 9: ...oose the control box with LJQ 1 LJQ 3 type Connectors 8 Maintenance and cleaning Do not change the PV components optionally diode junction box plug connectors Given a sufficient tilt at least 15 it is...

Page 10: ...iring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arc...

Page 11: ...anels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Road Industrial Zone Z...

Page 12: ...Power Pm W 390 395 400 405 Max Power Voltage Vmp V 40 6 40 8 41 41 2 Max Power Current Imp A 9 61 9 69 9 76 9 84 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 Short Circuit Current Isc A 10 08 10 16...

Page 13: ...s Fuse A 15 Electrical Performance STC Model Type ZXM6 H120 315 M ZXM6 H120 330 M Max Power Pm W 315 330 Max Power Voltage Vmp V 33 2 33 8 Max Power Current Imp A 9 49 9 77 Open Circuit Voltage Voc V...

Page 14: ...dule mm kg Dimensions mm Weight kg 1675x992x40 35 VDC Max System Voltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 H120 300 P Max Power Pm W 300 Max Power Voltage Vmp...

Reviews: