background image

P a g e  

3 | 14

 

 

 

● 

The electrical characteristics are within 

±

3 percent of the indicated values of Isc, Voc and Pmpp under 

test conditions (irradiance of 1000W/cm

2

,AM1.5 spectrum, and a cell temperature of 25

)   

Under normal conditions, a photovoltaic module is likely to experience conditions that produce more 

current and/or voltage than reported at standard test conditions. Accordingly, the values of ISC and VOC marked 

on this module should be multiplied by a factor of 1,25when determining component voltage ratings, conductor 

current ratings, fuse sizes, and size of controls connected to the PV output." 

● 

Installation should be in accordance with Australian installation standards AS3000

 

wiring rules and 

AS/NZS 5033. 

 

2、

Operating environment 

CLIMATE CONDITION 

Install the PV module in the following conditions: 

● 

Environment temperature

-20

  to 40 

℃。 

● 

Operating temperature

-40

  to 80 

℃。 

● 

Waterproof: don’t dip the modules into the water or continually explode under the water device or 

fountain.   

● 

Anti-corrosion: keep away from salt erode and sulfuration places. 

If there is exposure to salt (i.e., marine   

environment) and sulfur (i.e., sulfur sources, volcanoes), there is a risk of corrosion. It’s not recommended   

to install the modules, when the distance is less than 100m ; and it’s recommended to install the modules   

with the anti-salt function, when the distance is between 100m and 1km.

   

 Do not wear rings, jewelry, watches or other metallic items while working with photovoltaic 

modules. 

 

3、

Mounting and notes 

 

  The modules’ electrical performance in a system is the same. When connected in series, all modules 

must have the same amperage. When connected in parallel, the modules must all have the same 

voltage. Connect the quantity of modules that match the voltage specifications of the devices used in the 

system. The modules must not be connected together to create a voltage that is higher than the 

permitted system voltage.   

  To minimize risk in the event of an indirect lightning strike, avoid forming loops when designing the 

system.   

● 

Modules must not be fitted as overhead glazing. Ensure that the mounting system can also withstand 

the anticipated wind and snow loads.   

● 

Precipitate can run off through small openings on the back side of the module. Make sure that the 

openings are not masked after mounting.   

Summary of Contents for ZXM6-H144

Page 1: ...ration and maintenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and mainte...

Page 2: ...H120 ZXP6 H120 Max series fuse rating A 15 Nominal Mass 22 5kg 21 5kg 21kg 20 5kg 20 5kg 19 5kg Package Size mm 2000x992x40 35 2024x1002x40 35 2020x1002x40 35 2040x1002x40 35 1844x992x40 35 1860x1002...

Page 3: ...ces If there is exposure to salt i e marine environment and sulfur i e sulfur sources volcanoes there is a risk of corrosion It s not recommended to install the modules when the distance is less than...

Page 4: ...ns where the solar modules are mounted to a permanent structure the solar modules should be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will...

Page 5: ...he bolt and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or...

Page 6: ...secure the modules to support structure Always use all the eight mounting holes to secure the modules The module installed with screws on the front frame for load see the following picture and refer...

Page 7: ...can run off freely to avoid standing water or pudding This resistance value can decrease if modules are not mounted following the instructions above B Clamping installation Only for frame with 40mm t...

Page 8: ...just for reference Customer can select the corresponding installation manual based on the purchased module 7 Wiring The modules use thePV JX1203 type junction box This box on the back side of the modu...

Page 9: ...oose the control box with LJQ 1 LJQ 3 type Connectors 8 Maintenance and cleaning Do not change the PV components optionally diode junction box plug connectors Given a sufficient tilt at least 15 it is...

Page 10: ...iring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arc...

Page 11: ...anels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Road Industrial Zone Z...

Page 12: ...Power Pm W 390 395 400 405 Max Power Voltage Vmp V 40 6 40 8 41 41 2 Max Power Current Imp A 9 61 9 69 9 76 9 84 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 Short Circuit Current Isc A 10 08 10 16...

Page 13: ...s Fuse A 15 Electrical Performance STC Model Type ZXM6 H120 315 M ZXM6 H120 330 M Max Power Pm W 315 330 Max Power Voltage Vmp V 33 2 33 8 Max Power Current Imp A 9 49 9 77 Open Circuit Voltage Voc V...

Page 14: ...dule mm kg Dimensions mm Weight kg 1675x992x40 35 VDC Max System Voltage VDC 1500 A Max Series Fuse A 15 Electrical Performance STC Model Type ZXP6 H120 300 P Max Power Pm W 300 Max Power Voltage Vmp...

Reviews: