ZMC303 Motion Controller User Manual V1.5
“ZBasic Programming Manual” for details
.
(5)
According to their respectively instructions, correctly set the relevant parameters of
the third-party equipment to match the parameters of each node.
(6)
Correctly set the "address" and "speed" of the slave station expansion module
according to the manual of the slave station.
(7)
After all the settings are completed, restart the power supply of all stations to
establish communication.
(8)
Note that the "speed" settings of each node on the CAN bus must be consistent, and
the "address" settings cannot cause conflicts, otherwise the "ALM" alarm light will be
on, and the communication establishment will fail or the communication will be
disordered.
3.3.
RS232 Serial Port
RS232 is in one standard DB9 male socket and supports MODBUS_RTU protocol and
custom communication.