15
256
287
When IO number ranges of control card or expansion module repeat, only one is valid.
Therefore, it is recommended to configure CANIO_ADDRESS again to make them different.
ECI0032 is as CAN communication master station by default, but when it is used as
ZIO expansion module. If you need it is as CAN slave station, it is necessary to configure
CAN address and communication ratio again. It can configure CANIO_ADDRESS
parameter through online command.
For example:
CANIO_ADDRESS = 1
'set CAN ID to 1, at this time, it is slave station used for ZCAN slave station. 500KBPS
CANIO_ADDRESS = 2 +256
'set CAN ID to 2, at this time, it is slave station used for ZCAN slave station. 250KBPS
CANIO_ADDRESS = 3 +512
'set CAN ID to 3, at this time, it is slave station used for ZCAN slave station. 125KBPS
CANIO_ADDRESS = 4 +768
'set CAN ID to 4, at this time, it is slave station used for ZCAN slave station. 1MBPS
4.1.2.
CAN Expansion, Wiring of Master Station
ECI0032 supports ZCAN slave protocol, and it can be used as ZIO expansion
module for other controllers through ZCAN protocol.
Wiring reference (ECI0032 as the ZIO expansion module and it is connected to
controller):