ECI0032 Network IO Control Card User Manual V1.5
Impedance
4.7K
Ω
Voltage level
DC24V
The voltage to open
<14.5V
The voltage to close
>14.7V
Minimal current
-1.8mA (negative)
Maximum current
-6mA (negative)
Isolation mode
optoelectronic isolation
Note: the above parameters are standard values when the voltage of control card
power supply (E+24V port) is 24V.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of low-speed digital input IN (0-15) is shown in the figure above.
The external signal source can be an optocoupler, a key switch or a sensor, etc., all
can be connected as long as the requirements on output of electric level can be
achieved.
⚫
For the public end, please connect the "EGND" port on the power supply to the "COM"
terminal of the external input device. If the signal area power supply of the external
device and the power supply of the controller are in the same power supply system,
this connection also can be omitted.
3.2.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
Summary of Contents for ECI0032