p. 20/69
Figure 4.1. Ceramic flue gases directing element, which should be
positioned in the combustion chamber of the boiler;
Figure 4.2. Ceramic flue gases directing element is positioned in the
combustion chamber of the boiler;
ATTENTION: at the mounting and installation of the ceramic element
should be done with care and preventive measures should be taken in
order to keep this element’s integrity. After the element has been installed
in the combustion chamber, it should be pushed backwards in order to
touch the back vertical plate of the heat exchanger.
o
Install the thermovalve, which controls the air flow rate;