CANFDNET-200U
High-Performance Dual-Channel Ethernet to CAN (FD) Converter User Manual
©2021 Guangzhou ZLG Electronics Co., Ltd.
26
User Manual
CAN (FD) to Ethernet
CAN (FD) to
Ethernet
-
CAN (FD) message to Ethernet settings, that is,work mode
settings. See Table 7.13. Select View advanced configuration to
view more settings
Vehicle Ethernet to
Ethernet
Vehicle Ethernet
to Ethernet
-
Vehicle Ethernet to Ethernet settings. See Table 7.14
Table 7.11 Filter setting description
Property Name
Default
Parameter Description
Filter conditions
Within the specified ID
range (whitelist)
Within the specified ID range (whitelist): Frames within the preset ID range will be
received;
Beyond the specified ID range (blacklist): Frames within the preset ID range will not be
received.
Enable
Disable
Select the corresponding item to enable.
Frame type
Standard frame
Standard frame: Set the filter message type to standard frame;
Extended frame: Set the filter message type to extended frame.
Start ID
0
Start ID of the filtered message, expressed in hexadecimal notation
End ID
0
End ID of the filtered message, expressed in hexadecimal notation
Table 7.12 Description of the setting of timed sending interface
Property Name
Default
Parameter Description
Enable
Disable
Selecting
means enabling.
ID
0
Message ID, expressed in hexadecimal notation.
Sending cycle
1000
Timed sending period, in ms.
Number of Sending
0
The number of times a message is sent. The value ranges from 0 to 65535. When it is
0, it means an unlimited number of sending times.
Frame type
Standard frame
Send message type, standard frame or extended frame.
Frame format
Data frame
Send message format, data frame or remote frame.
Frame protocol
CAN
Send message protocol, CAN or CANFD;
When the controller type is CAN, only CAN can be selected.
CANFD
acceleration
-
When the frame protocol is CANFD, this item is valid; acceleration or no acceleration
can be selected.
Data
-
Send message data, hexadecimal, separated by spaces.
Table 7.13 CAN(FD) to Ethernet interface description
Property Name
Default
Parameter Description
Enable
-
Selecting
indicates enabling; one enable item is selected by default.
Work mode
TCP server
TCP Server: The device acts as a server and waits for client connections;
TCP Client: The device as a client actively connects to the target server;
UDP: The device uses UDP for communication and does not need to establish a
connection.
Local port
8000
Local working port. The value ranges from 0 to 65535. When it is 0, the system
randomly allocates ports. When the work mode is TCP Server or UDP mode, the port
cannot be set to 0;