CANFDNET-200U
High-Performance Dual-Channel Ethernet to CAN (FD) Converter User Manual
©2021 Guangzhou ZLG Electronics Co., Ltd.
12
User Manual
Figure 5.4 Device configuration display
5.3.3 Configuring Parameters
Whether the parameter configuration is correct or not will directly affect the normal communication. The
common parameter configurations are described below.
⚫
Network parameters
Before using the PC to communicate with the device, ensure that an Ethernet card is installed on the user's
PC, and the PC and the device must be in the same network segment. The device is set with a default IP address
(192.168.0.178) and network mask (255.255.255.0) when it leaves the factory. Check whether the device is in the
same network segment as the user's PC according to the process shown in Figure 5.5 Same Network Segment
Detection Flowchart 5.5.
PC
机子网掩码
?
PC
机
IP
地址
?
PC
机所属子网
?
设备
IP
地址
192.168.0.178
设备子网掩码
255.255.255.0
比较
设备所属子网
192.168.0.0
调整
PC
机
IP
地址
可以设置设备
与
与
不相同
相同
Figure 5.5 Same network segment detection process
There are two methods to keep the user's PC and device in the same network segment.
The first method is to change the IP address of the PC. Open [Control Panel] on the PC, double-click the
[Network Connection] icon, click to select the [Local Area Connection] corresponding to the network card of the
connected device, right-click and choose [Properties]. Double-click on the pop-up page to select [Internet