SBTL5000 series User Manual
P a g e
|
5
2.2
Installation position of the swing barrier
A distance of 100mm between the swing barrier turnstile and the wall needs to be reserved for ease
of opening the top cover of the machine to perform maintenance and adjustment. The reference
figure as below:
Figure 2-2 SBTL5000 series dual-lane
2.3
Cables installation and fixing
For the outlets of the concealed cables, please refer to the drawing showing the mounting holes. The
input voltage for this swing barrier turnstile is
AC100-120V/200-240V
and its master and slave are
connected by a
5-core cable (signal) and a 2-core cable (power)
. When installing this swing barrier
turnstile, the user only needs to connect it to the corresponding ports. Note that the PVC conduits are
buried
100mm
under the ground, with the height of the exposed part not exceeding
100mm
. In
addition, the conduit outlet is bent back to prevent ingress of water into the conduit.
SBTL 5000 series installation holes and cabling positions as shown in Figure 2-3a: