Chapter 5 Common failure analysis
Number
Failure phenomena
Analysis and solution
1
Direction indicator no response or
indication is not correct.
Check whether the connection to the roof lamp is
correct or not.
2
After swipe the card there is only a
swing arm action.
Check the type setting and the 6 core connection
line of main and auxiliary machine.
3
Barrier opens after a long time
without closing.
Check whether the time of the opening is too long.
4
Swing the arm swing at zero
position.
This situation may be caused by the thirteenth sets
of the menu is too large. To decrease the value of the
thirteenth items may solve the problems.
5
Serious malfunction. Pendulum rod
rotation is out of preset range,
please do zero correction.
User needs to correct the zero position, left open
position and right open position in seventh items.