Chapter 4 Menu Instruction 

There are 4 keys on the LCD screen, including "UP”, "DOWN", "ENT", and "CANCEL". "UP" and "DEC" are reset 

keys, each of which has two functions. When menu operations are not used, "UP" and "DEC" can be used to 

open the barrier to left or right. 

When you press the "ENT" key, the system will prompt you to enter the 

password, the password is "UP" two times,  "DEC"  four times, then press "ENT" to enter the menu 

operation system. 

After the "ENT" key is pressed to enter the menu operation system, "UP" and "DEC" cannot be used to open 

the barrier to left or right, but used for moving up and down on the menu to select an option.   

If the barrier is not in right position, we need to set the position of the barrier

   

Set barrier position:   

       1: zero position.

the position when the barrier is closed

 

       2: left open position. (the position when the barrier is open to left) 

       3: right open position. (the position when the barrier is open to right) 

Methods for setting the zero position of the swing boom: First press "ENT" and the menu is displayed. Then 

press "UP" to move to Option 7 on the menu. Press "ENT" to make it available for value modification and then 

press "UP" to set the value to 1. Turn the swing boom to the desired zero position 

Perpendicular to the 

chassis

allowable deviation of 1 degrees

. Finally press "ENT" and the system gives a restart prompt. Zero 

calibration is finished.(restart the machine after setting zero position.) 

      Procedures for setting the left opening position of the swing boom: First press "ENT" and the menu is 

displayed. Then press "UP" to move to Option 7 on the menu. Press "ENT" to make it available for value 

modification and then press "UP" to set the value to 2. Move the swing boom of the gate to the desired 

position on the left-hand side. Finally press "ENT" and the system will record this position as the left open 

position. 

      Procedures for setting the right opening position of the swing boom: First press "ENT" and the menu 

is displayed. Then press "UP" to move to Option 7 on the menu. Press "ENT" to make it available for value 

modification and then press "UP" to set the value to 3. Move the swing boom of the gate to the desired 

Summary of Contents for ProEntrance Series

Page 1: ...Quickly Installation Guide 1 INSTALLATION GUIDE ProEntrance series Swing Barrier Applicable Models ProEntrance SB 01RF 01FP 02RF 02FP Version 1 0 Date 9 2017 ...

Page 2: ...roximately 100mm and 30mm 2 Put the wire through the pipe 3 In order to avoid the impact on communication 220V 110V power line high voltage and signal line low voltage should be separated The ground wire must be connected ProEntrance series SB installation holes and cabling positions as shown in Figure 1 1 Figure 1 1 ...

Page 3: ...you can start the installation procedures If an exception occurs please contact your vendor for information 2 2Cables Installation For the outlets of the concealed cables please refer to the drawing showing the mounting holes The input voltage for this swing barrier turnstile is AC100 120V 200 240V and its master and slave are connected by a 6 core cable When installing this swing barrier turnstil...

Page 4: ... according to the following wiring diagram Figure 3 1 The connection of slave Black GND Green TX White RX Red 24V The connection of master Black GND White RX Green TX Red 24V The yellow and orange wires are prepared for access control system ...

Page 5: ...the swing boom First press ENT and the menu is displayed Then press UP to move to Option 7 on the menu Press ENT to make it available for value modification and then press UP to set the value to 1 Turn the swing boom to the desired zero position Perpendicular to the chassis allowable deviation of 1 degrees Finally press ENT and the system gives a restart prompt Zero calibration is finished restart...

Page 6: ...5 position on the right hand side Finally press ENT and the system will record this position as the right opening position ...

Page 7: ...n line of main and auxiliary machine 3 Barrier opens after a long time without closing Check whether the time of the opening is too long 4 Swing the arm swing at zero position This situation may be caused by the thirteenth sets of the menu is too large To decrease the value of the thirteenth items may solve the problems 5 Serious malfunction Pendulum rod rotation is out of preset range please do z...

Page 8: ...istered trademark of ZKTeco or a related company All other product and company names mentioned are used for ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhen China 518129 Tel 86 755 89602345 Fax 86 755 89602394 www zkteco com ...