background image

Safety Precautions 

Product Contents 

Product PIN Diagram  

LED indicators 

Product Dimension 

Installation of  Panel with Casing 

Wire Legend 

Power Wiring Diagram 

WEIGAND Connection 

Exit button Connection 

Lock connection 

Door Sensor Connection 

Aux. Input Connection  

Aux. Output Connection  

Ethernet Connection 

RS485 Connection 

DIP switch settings 

Electrical Specifications 

Troubleshooting 

Specifications 

02 
04 
06 
06 

07 

08 
09 
10 
11 

11 

12 

12 
14 

14 
15 

16 

17 

18 
19 

20 

Summary of Contents for C3-200

Page 1: ...www zkteco com ...

Page 2: ... Legend Power Wiring Diagram WEIGAND Connection Exit button Connection Lock connection Door Sensor Connection Aux Input Connection Aux Output Connection Ethernet Connection RS485 Connection DIP switch settings Electrical Specifications Troubleshooting Specifications 1 02 04 06 06 07 08 09 10 11 11 12 12 14 14 15 16 17 18 19 20 ...

Page 3: ...itor or speaker may damage the device Do not place the device next to heating equipment Be careful not to let liquid like water drinks or chemicals leak inside the device Clean the device often to remove dust on it 01 02 03 04 05 06 Do not let children touch the device without supervision The list below is to keep user s safety and prevent any loss Please read carefully before installation ...

Page 4: ...allation Do not drop the device Do not use the device for any other purpose than specified Do not disassemble repair or alter the device 07 08 In cleaning do not splash water on the device but wipe it out with smooth cloth or towel 09 Contact your nearest dealer in case of a problem Do not damage the device 10 11 12 ...

Page 5: ...4 Product Contents Basic Contents C3 200 Wall mounting screws 2 pcs Wall Plugs 2 pcs Surge Suppressing Diode 4 pcs screw driver 2 pcs Software CD C3 installation guide ...

Page 6: ...5 Product Contents Optional accessories Weigand Card Reader Prox Card Card enroller Door Sensor K1 1 Exit Button Alarm C3 Metal Case RS485 convertor ...

Page 7: ...TCP IP communication is normal ACT Yellow Flashing LED indicates data communication is in progress PC RS485 Yellow Green Flashing LED is sending or data in communication progress POWER Red Flashing LED indicates the panel is powered on RUN Green Flashing LED indicates that panel is in normal working state CARD Yellow Flashing LED indicates that the card is read by the panel Reserved 485 LED Status...

Page 8: ...00 Product Dimension Dimension L W 203 2 106 mm 6 30 4 17 inches 160mm 6 30in 106mm 4 17in C3 Casing 400mm 15 7in 330mm 13 0in 330mm 13 0in 90 5mm 3 56in Dimensions L W H 400 90 5 330 mm 15 7 13 0 3 56 inches ...

Page 9: ...allation of Panel Case Metal Case Heat dissipation Hole Cable Conduit Box Lock Hole Power Supply Backup Battery C3 Panel Thread Hole Wires need to be passed through this conduit Mounting the case on the wall ...

Page 10: ... Legend 9 Detector Infrared sensors 1Exit Switch 1Card Reader 2 K1 1 Exit Switch 2 Card Reader 12V Power Supply Normal Close Lock Normal Open Lock Alarm RS485 Convertor LAN Cable Floodlight 12V DC Power DC ...

Page 11: ...Power wiring diagram 10 AC AC Switching power supply C3 200 AC AC Switching power supply C3 200 Backup Battery Without Backup Battery With Backup Battery 110 220V 110 220V ...

Page 12: ...nd Connection 11 Weigand Card Reader Exit Button Connection Beeper Green LED Weigand D1 Weigand D0 GND DC 6 14V BUT GND DV12V DV12V NO COM NC separate power supply Notice ZK ABK Exit Button K1 1 Exit Switch ...

Page 13: ...12 Lock Connection Built in Power Supply Built in Power Supply Sensor Sensor GND 12V DC 12V DC GND Sensor Sensor GND 12V DC 12V DC GND FR107 FR107 For Normally Open Lock For Normally Close Lock ...

Page 14: ...wer supply you must do the following 1 Select the wanted lock relay and find its jumpers 2 Take off the jumpers and change to 3 Connect the lock as shown in the diagram below Steps C3 200 Select one Relay FR107 GND 12V DC SEN SEN GND 12V DC 4 Lock Relays Default setting 1 5 Take off jumpers Jumpers Plug Jumpers Changed setting 5 1 Connecting a lock with external power supply ...

Page 15: ...14 Aux I O connection Aux Input Connection Aux output Connection COM NO NC GND 12V DC COM NO NC GND 12V DC ...

Page 16: ...0 ft 3 For cables length of more than 100m use HUB to amplify the signal TCP IP CR10 Card Issuer The CR10 is connected to the server using USB connection To connect C3 200 with a PC directly connect both devices with a straight network cable As the C3 200 supports auto MDI MDIX it is not necessary to use a crossover type cable CR10 Card Issuer C3 200 C3 200 ...

Page 17: ...ing communications 2 A single 485 bus can be connected with 63 access control panels at the most but preferably less than 32 panels should be connected 3 To eliminate signal attenuation in communication cables and suppress interference if the bus is longer than 200 meters set the number 8 DIP switch to the ON position This is equivalent to a parallel connection of one 120ohm resistance between the...

Page 18: ... C3 IP address or the device does not work normally you can use the number 7 terminal to restore C3 200 to factory default settings The parameters which gets reset are device IP address communication password gateway subnet mask 2 The switch is OFF by default When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position the factory settings will be r...

Page 19: ...6V Use regulated DC power adaptor only Switching Current A 2 Auxiliary relay output Switching voltage V 36V Use regulated DC power adaptor only Switching Current A 1 25 Switch Aux input VIH V TBD VIL V TBD Pull up resistance Ω 4 7k The input ports are pulled up with 4 7k resistors WIEGAND Input Voltage V 10 8 12 13 5 Current mA 500 ZK Electronic lock Voltage V 10 8 12 13 2 Current mA 500 ...

Page 20: ...default However there are 9 other bit formats which can be selected from the software In addition you can also define your custom bit format 3 How many verification mode can be support Card only Password only Card plus password 4 Can we integrate IP Camera and NVR Currently ZKACCESS software supports ZKAccess IP Cameras and NVR You can associate a camera to the door and setup a linkage for the sam...

Page 21: ...our Door four door one way two door two way Number of readers supported 4 Types of readers supported 26 bits WIEGAND others upon request Number of Inputs 6 2 Exit Device 2 Door Status 2 AUX Number of Outputs 4 2 Form C relay for lock and 2 Form C relay for Aux output Weight 7 8lbs 3 55kg Enclosure Stainless Steel Mounting Wall Mount Dimensions Bundle Only 15 7in 3 56in 13 0in 400mm L X 90 5mm W X ...

Page 22: ... OFF 27 ON ON OFF ON ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF 32 OFF OFF OFF OFF OFF ON Place Address Switch Setting 1 2 3 4 5 6 Address No 1 2 4 8 16 32 33 ON OFF OFF OFF OFF ON 34 OFF ON OFF OFF OFF ON 35 ON ON OFF OFF OFF ON 36 OFF OFF ON OFF OFF ON 37 ON OFF ON OFF OFF ON 38 OFF ON ON OFF OFF ON 39 ON ON ON OFF OFF ON 40 OFF OFF OFF ON ...

Page 23: ...ss Inc All right reserved ZKTeco May at any time and without notice Make changes or improvements to the product and services offered and or cease producing or commercializing them Functions and specifications of the product are subject to change without notice due to quality enhancement or function update For any inquiry for the product please contact ZKTeco Inc ...

Reviews: