L9000 Fingerprint Lock User Manual
For this parameter, its unit of quantity is 1 second and value range is 3-15, that is,
3-15 seconds.
Note:
The unit of quantity and the maximum value of this parameter here are
standard configurations. If you need larger parameter values, please consult our
commercial representatives or pre-sales technical support engineers.
Verify Mode:
Press
OK
key to display the setting interface, and then press
S
/
T
key to select the value. There are three optional values 0, 1, and 2 that represent
different matching modes respectively, and the default value is 1.
Verify Mode 0
: Only the administrator can open the lock, while the unlocking
function is disabled for ordinary users.
Verify Mode 1
: This is a default matching mode. Users can open the lock by
successfully matching their fingerprints or password only once.
Verify Mode 2
: This is a dual verification mode. The administrator can open the
lock by successfully matching his/her fingerprint or password only
once, but an ordinary user has to pass the verification in any two
matching modes by using the same ID. For detail, please see
Appendix 1 Introduction about Verify Mode 2.
Normal Open
: Press
OK
key to display the Normal Open setting interface, and
press
S
/
T
key to select
Y
(Yes) or
N
(No). If you select
Y
, a prompt will be
displayed after unlocking, inquiring whether you desire to select Normal Open. For
detail, please see
2.4 User Verification and Set Normal Open Status.
To disable the Normal Open function
, power on the system and press
OK
key in
the Normal Open interface. Then the system closes the lock and automatically
powers off.
CLOSE DOOR
: Press
OK
key to enter the setting interface, and then press
S
/
T
key to select
Y
or
N
. If select it as Y.
Door closing prompt:
When the user is
verified successfully and the door is opened, if the door is not closed for a period of
time, the screen will prompt the user to close the door and the buzzer will give a
brief alarm.
Reserve the rights of modification and explanation
28