background image

for the temperature to stabilize before operating if the unit has been moved from one area to
another where there is a 5°F change or greater (ex. from an air-conditioned building outside on a
warm day).

6. For maximum accuracy, only use the device on fully cured concrete.

 

CAUTION:

1. Always turn off power when working near electrical wires.

2. In situations involving multiple, closely spaced targets, the MetalliScanner® metal finder may be
unable to detect the exact location and/or depth of each piece of metal. Always use caution and
wear safety glasses when nailing, cutting or drilling in walls, floors, and ceilings that may contain
metal objects.

3. If a magnetic and non-magnetic object (ex. rebar and copper pipe) are positioned side-by side or
on top of each other, the tool may have difficulty locating them.

Summary of Contents for MetalliScanner 6.0

Page 1: ...2 Calibration Switch 3 Crosshairs 4 Liquid Crystal Display 5 Battery Compartment LCD Components 1 Depth Bars 2 Depth Numbers 3 Magnetic Icon 4 Low Battery Indicator 5 Plus Minus Sign 6 Scanning Wheel...

Page 2: ...cator and two mode icons The low battery indicator is displayed as a warning when the battery has less than five hours of use remaining The magnetic icon is displayed when the unit is in the magnetic...

Page 3: ...interferes with determining the exact location of the target you can press the calibration button when you think you are over the target and then try to locate that target more precisely NOTE 1 You th...

Page 4: ...ge to the plus sign Continue scanning in this direction until the plus sign again changes to the minus sign and the unit beeps at approximately the same location Figure 4 The greatest number of depth...

Page 5: ...een poured at different times Result Cannot rely on a single calibration for the entire area Action to be taken Pre scan each segment separately calibrate and determine depth of targets for each segme...

Page 6: ...normal a calibration error has occurred Reposition the tool and recalibrate 2 If a metal target was located during pre scan and the MetalliScanner metal finder does not locate it after calibration th...

Page 7: ...onstant light pressure Changes in pressure can cause inaccurate fluctuations in the scanning wheel display 2 When the Low Battery Indicator appears on the display replace the battery as soon as possib...

Page 8: ...hen working near electrical wires 2 In situations involving multiple closely spaced targets the MetalliScanner metal finder may be unable to detect the exact location and or depth of each piece of met...