![Zip VP303 Installation, Maintenance And User Instructions Download Page 4](http://html1.mh-extra.com/html/zip/vp303/vp303_installation-maintenance-and-user-instructions_4039507004.webp)
Dimensions
Varipoint
Capacity
Width
Height
Depth
Weight
Weight
(litres)
(mm)
(mm)
(mm)
Empty (kg) Full (kg)
VP303
34
430
620
448
16
50
VP503
50
430
808
448
20
70
VP803
80
485
946
503
27
107
VP953
100
485
1091
503
33
133
Typical Installation
Parts List
To drain via tundish
Cold water supply
To drain via tundish
Hot water outlet
1
2
9
3
4
5
6
7
8
1
Temperature and pressure relief valve
2
Combined pressure reducing valve and strainer
3
Expansion relief and check valve
4
Balanced cold water take off
5
Expansion vessel
6
Tee piece and drain valve
7
Temperature control
8
Neon indicator
9
Service valve (not supplied)
Zip Varipoint III Installation, Maintenance and User Instructions - August 2008
5