807042 v1.00 03.21 HydroTap G5 UltraCare Install Instruct

Operation & maintenance

Please refer to the User Guide for all operational and maintenance features of 
the HydroTap. The User Guide is located in the HydroTap Command Centre 
filter door.

Do not use strong, corrosive or abrasive cleaning 
materials on the HydroTap tap or Command Centre.
Do not use “self-drying” disinfectant sprays.
Wipe external surfaces with a damp cloth or 
antibacterial alcohol wipe, then immediately wipe 
dry with a clean, dry microfibre cloth or paper towel. 
Food-grade disinfection wipes may be used to clean 
within the tap dispensing outlets.

Cleaning

In order to help preserve our environment we ask that 
you dispose of this product correctly. Please contact 
your local city council for collection centre details. 

End of life disposal

In Australia, Zip offers a fully-inclusive HydroCare Service Plan to take care of 
all routine maintenance, including filter replacements, sanitisation, electrical 
safety inspections as well as general maintenance of your HydroTap. For more 
information, visit our website: 

zipwater.com/HydroCare

The Zip filter should be replaced as recommended on the filter, or earlier if 
you notice a persistent reduction in water flow from the tap or an increase in 
chlorine, taste or odour in the water. Not changing the filter cartridges when 
required may affect the water quality.

For safe operation after periods of non-use longer than 72 hours, flush the 
HydroTap for at least 60 seconds.

Summary of Contents for UltraCare BCU40

Page 1: ...1 807042 v1 00 03 21 HydroTap G5 UltraCare Install Instruct Model UltraCare BCU40 Installation Instructions Zip HydroTap G5 PRODUCTLABEL Visit our website to download the manuals Australia...

Page 2: ...19 Cleaning 19 End of life disposal 19 Thank you for choosing Zip HydroTap Enjoy filtered boiling and chilled water from the Zip HydroTap The HydroTap Command Centre installed under the bench has a co...

Page 3: ...ple portable socket outlets or portable power supplies at the rear of the appliance 8 Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the po...

Page 4: ...technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson Venting Occasionally steam and or boiling water may discharge through a vent outlet on...

Page 5: ...ses Classic tap shown part no 91519 BC chrome 1 x HydroTap Command Centre including water filter cartridge 1 x mains water braided hose part no 90056 Side Duct part no 91505 Vent Kit BC Model 1 x Inle...

Page 6: ...ving jurisdiction The system is only designed to reduce normally occurring non pathogenic nuisance microorganisms Class B systems are not intended for treatment of contaminated water UltraCare BCU40 C...

Page 7: ...are required The appliance must be connected to a potable water supply with min max working pressure as outlined in the Technical specifications with isolating valve within reach of the hose and posit...

Page 8: ...Tap Command Centre Mains power supply to Command Centre Power for UV C Module Vent tray Side duct Mains water inlet isolation valve not supplied Step 1 Positioning Ensure there is adequate space in th...

Page 9: ...out in cabinet oor Inlet vent options Fit the silicone door buffers to the inside edge of the cupboard door to provide an air space Step 2 Ventilation IMPORTANT Allow a minimum clearance envelope of...

Page 10: ...ted with a drain 3 1 Pass the hoses down through the hole and locate the tap in place 3 4 From below the benchtop push the washer over the hoses and threaded rod then push the spider clamp onto the th...

Page 11: ...Flush water supply lines before any plumbing connections are made to prevent sediment from affecting operation Connect electrical cable to the side of the Command Centre Power must remain OFF until co...

Page 12: ...UE hose from tap Push at least 15mm over the fitting Connect USB C cable from UV C Module to HydroTap Ensure hose has constant fall Connect 12V power supply to HydroTap Power must remain OFF until com...

Page 13: ...ection Push the hose over the connector for a minimum of 15mm There a constant fall from the tap down to the Command Centre Hoses must be trimmed to avoid loops and kinks Take care when positioning be...

Page 14: ...filter factory setting With external filter Set bypass valve optional The bypass valve diverts the boiling feed water to external filtration optional internal filter is supplied with the unit The valv...

Page 15: ...urn electrical power ON at both the power outlets 6 2 Step 6 Commissioning 10L bucket not supplied Open valve to let water flow Close valve when complete Do not commission your HydroTap until it is re...

Page 16: ...ch requires the product to be flushed with fresh water at installation as shown on the Command Centre screen Each tank boiling and chilled must be emptied and filled three times For countertop font in...

Page 17: ...p Service Cold sensor Closed Internal fault Call Zip Service Flood sensor Open Internal fault Call Zip Service Condenser sensor Closed Internal fault Check Ventilation Call Zip Service Condenser senso...

Page 18: ...ools down and reports that its internal temperature has returned to 40 C or lower UV Under Current Tried to dispense cold water and current of UV C Module not at minimum threshold a The 12V external p...

Page 19: ...help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details End of life disposal In Australia Zip offers a full...

Page 20: ...efer to User Guide for operation and maintenance ZipWater Australia PtyLtd ABN46000578727 67 77AllinghamStreet CondellParkNSW2200 Postal LockedBag80 Bankstown1885 Australia Tel 612 97963100 Freecall18...

Reviews: