807042 v1.00 03.21 HydroTap G5 UltraCare Install Instruct
Boiling calibration
Caution: hot steam may vent from the tap spout.
Boiling calibration will optimise the performance of the boiling unit. The
procedure will take approximately 10 minutes.
Upon completion, the External Booster screen will appear.
For best product performance, ensure the correct selection for the
booster:
• YES: booster is installed, OR
• NO: booster is not installed.
Commissioning
6.5
Tank flush (UltraCare models)
The HydroTap Command Centre is factory-sanitised. Residue from the
sanitising liquid may remain in the product, which requires the product
to be flushed with fresh water at installation, as shown on the Command
Centre screen. Each tank (boiling and chilled) must be emptied and filled
three times.
• For countertop font installations, ensure the dispensed water can
drain freely, or prepare a large container to collect the dispensed
water and remove it for disposal.
• Use the tap to dispense water from the tanks.
Caution: hot water may be dispensed. The “Safety lock” on the tap
must be covered in order to dispense from the boiling tank.
• Refer to the screen to view the current tank levels and the number
of tank flush cycles completed. If required, press the arrow icon to
restart the tank flush process.
• Once the tank flush is complete, the NEXT button appears. Press
NEXT to continue to the boiling calibration screen.