4

805757 v1.05 06.21 Miniboil Install Instructions

WARNINGS AND PRECAUTIONS

!

For continued safety of this appliance it must be installed, operated 
and maintained in accordance with the manufacturer’s instructions.
This appliance may deliver water at high temperature. Refer to the 
Plumbing Code of Australia (PCA), local requirements and installation 
instructions to determine if additional delivery temperature control is 
required. 

•  All plumbing must comply with AS3500.4.1 &  AS3500.4.2
•  All electrical must comply with AS3300 wiring rules

Safety

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible 
for their safety. Children should be supervised to ensure they do not 
play with the appliance

Qualifications

If any power cord or plug is damaged it must be repaired only by a 
qualified technician. To avoid hazards, all installation procedures 
must be carried out by a suitably qualified trades person. The power 
cord and general power outlet must be in a safe visible position for 
connection.

Venting

Sometimes steam and / or boiling water may discharge through a vent 
outlet at the mouth of the tap. If the tap is not installed using the Font 
pedestal, ensure the tap body is located so the tap outlet safely drains 
into the sink bowl area. 

Lifting

Take care when lifting the Command Centre. Some units may 
exceed safe lifting limits. Do not lift without assistance. The weights 
of the units are given in the table under the heading “Installation 
Requirements”. 

Airflow

The ambient temperatures this unit should operate within are 5ºC 
-  35ºC. The system will operate satisfactorily only if the recommended 
air gaps are provided, as noted in the installation procedure. 

Intended use

This appliance is intended to be used in household and similar 
applications such as: staff kitchen areas in shops, offices and other 
working environments; by clients in hotels, motels and other 
residential-type environments; catering and similar non-retail 
applications.

Frost protection

If this appliance is located where the ambient air temperature could 
fall below 5ºC, do not turn off the appliance electrically. This safeguard 
does not offer the same protection to the connecting pipework and 
fittings.

The power point must be 
located within reach of its 
cable. The appliance must be 
positioned so that the plug is 
accessible.

Zip Miniboil Command 
Centre.

The appliance must be 
placed on a horizontal 
surface in an upright 
position, as shown above.

This way up

Summary of Contents for Miniboil BA

Page 1: ...1 805757 v1 05 06 21 Miniboil Install Instructions Installation instructions user manual Zip Miniboil AFFIX PRODUCT LABEL HERE 805757 Models Boiling Ambient Boiling Only...

Page 2: ...of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connecting 3 Check all plumbing fittings have been tightened 4 Ensur...

Page 3: ...lation requirements 5 Special tools required 6 Installation 6 Step A Installing the tap 6 Step B Installing the filter 7 Step C Installing the Command Centre 7 Step D Connecting the water supply 7 Ste...

Page 4: ...s steam and or boiling water may discharge through a vent outlet at the mouth of the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely dra...

Page 5: ...site Sufficient space in the cupboard to install the command centre in accordance with these Installation Instructions NOTE Allow clearance of 50 mm around all sides and 200mm above the command centre...

Page 6: ...ture seal against the bench sink top A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit 4 Pass the hoses through the 35mm hole and carefully locate the Hea...

Page 7: ...essary for efficient operation Adjust cupboard door hinges and attach the supplied silicone door buffers to create a 4 mm air gap between the doors and the cupboard This is the minimum ventilation req...

Page 8: ...ntre It should be fitted together tightly until a click is felt Failure to fully insert the connector will prevent tap operation Once connected fix the cable to the wall ensuring it is off the floor a...

Page 9: ...be dispensed All LEDs Fault Flashing there is a fault in the unit In that case switch off the unit for at least 20 seconds If the fault has not been corrected when the unit is switched on again contac...

Page 10: ...ed as follows 1 Turn off the water supply 2 Use the tap to dispense ambient and hot water until no more water flows to empty the system 3 Disconnect the appliance from the power supply After prolonged...

Page 11: ...ed on Check for loom connection Slow water recovery after use Unit is in Sleep Mode Possible internal fault Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Cont...

Page 12: ...7 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications...